Máy đo công suất sóng RF và Viba Tektronix PSM5120 (100 MHz - 8 GHz, N-male)

Hãng sản xuất Tektronix
Model: PSM5120

Hiển thị kết quả lên máy tính qua cổng USB
Dải tần:  100 MHz - 8 GHz
Giải đo: –60 dBm - +20 dBm
Chức năng đo: Average (CW) Power Measurement; Duty Cycle Corrected Pulse Measurement; Peak Power, Pulse Power, Duty Cycle Measurement; Peak and Average Burst Power Measurement; Measurement Logging; Pulse Width, Rise/Fall, Overshoot, Droop Measurement; Time Gate Measurements; Pulse Waveform Display with Markers Measurement
Kiểu kết nối tín hiệu: N-male
Cung cấp kèm theo:  Máy đo có cảm biến kết nối USB, chứng chỉ của hãng, calibration data report, 2 m cáp USB, hướng dẫn cài đặt , USB flash drive.

Chi tiết

 

Datasheet

PSM5000 Series USB Power Meters (Average/Peak/Pulse + Profiling)

Characteristic

PSM5110

PSM5120

PSM5320

PSM5410

Input Connector

3.5 mm, male

N-type, male

N-type, male

3.5 mm, male

Frequency Range

100 MHz to 8 GHz

50 MHz to 18.6 GHz

50 MHz to 20 GHz

Dynamic Range

100 MHz to 6 GHz: –60 dBm to +20 dBm

6 GHz to 8 GHz: –50 dBm to +20 dBm

–40 dBm to +20 dBm

Maximum Peak-to-Average Ratio

100 MHz to 6 GHz: 80 dB

6 GHz to 8 GHz: 70 dB

55 dB

Internal Video Bandwidth

10 MHz, typical

Timebase

±50 ppm, typical

Real-time Sample Rate

500 kS/s

Average Power, Minimum Pulse Width

500 ns, typical

Peak Power, Minimum Pulse Width

200 ns, typical

Pulse Profiling, Maximum Equivalent-time Sample Rate*4

48 MS/s

Pulse Profiling, Minimum Rise Time, 10% to 90%

54 ns (–70 dBm to –20 dBm pulse, 4 GHz)

Pulse Profiling, Minimum Fall Time, 90% to 10%

44 ns (–70 dBm to –20 dBm pulse, 4 GHz)

Pulse Profiling, Manual Trigger Level Accuracy

±1 dBm

Pulse Profiling, Minimum Number of Cycles

2 cycles

Pulse Profiling, Video Filters

100 kHz, 200 kHz, 300 kHz, 500 kHz, 1 MHz, 2 MHz, 3 MHz, 5 MHz, 10 MHz

Total Accuracy*1

Total Uncertainty = 2 × √[ (CF/2)2 + (L/2)2 + (N/2)2 + (Z/√2)2+ (Mm/√2)2 + (T/√2)2 ]

   Calibration Factor Uncertainty (CF)

100 MHz to 500 MHz: 4.0%

500 MHz to 8 GHz: 2.5%

100 MHz to 500 MHz: 4.0%

500 MHz to 8 GHz: 1.7%

50 MHz to 500 MHz: 4.0%

500 MHz to 10 GHz: 1.7%

10 GHz to 18.6 GHz: 1.9%

50 MHz to 500 MHz: 4.0%

500 MHz to 12.5 GHz: 2.6%

12.5 GHz to 18 GHz: 3.2%

18 GHz to 20 GHz: 3.5%

   Linearity Uncertainty (L)

100 MHz to 2 GHz

+15 dBm to +20 dBm: 7.0%

+5 dBm to +15 dBm: 5.0%

–60 dBm to +5 dBm: 3.0%

 

2 GHz to 8 GHz

+15 dBm to +20 dBm: 5.0%

+5 dBm to +15 dBm: 3.0%

–60 dBm to +5 dBm: 2.0%

50 MHz to 100 MHz

+15 dBm to +20 dBm: 7.0%

–40 dBm to +15 dBm: 5.0%

 

100 MHz to 2 GHz

+15 dBm to +20 dBm: 7.0%

+5 dBm to +15 dBm: 5.0%

–40 dBm to +5 dBm: 3.0%

 

2 GHz to 20 GHz

+15 dBm to +20 dBm: 6.0%

+5 dBm to +15 dBm: 4.0%

–40 dBm to +5 dBm: 2.0%

   Noise Uncertainty (N)

1 second integration

+10 dBm to +20 dBm:

0.15% (100 MHz to 8 GHz)

 

–30 dBm to +10 dBm:

0.04% (100 MHz to 8 GHz)

 

–50 dBm to –30 dBm:

0.04% (100 MHz to 6 GHz)

0.15% (6 GHz to 8 GHz)

 

–60 dBm to –50 dBm:

0.15% (100 MHz to 6 GHz)

5 second integration

+10 dBm to +20 dBm: 1.5% (50 MHz to 20 GHz)

–20 dBm to +10 dBm: 1.0% (50 MHz to 20 GHz)

–30 dBm to –20 dBm: 1.5% (50 MHz to 20 GHz)

–40 dBm to –30 dBm: 7.0% (50 MHz to 18.6 GHz)

   Zero Offset Power*2 (Z)

[(0.35 nW at 25 °C) + |ΔT| × (0.025 nW / °C)] + 0.005 nW / month

50 MHz to 500 MHz

[(200 nW at 25 °C) + |ΔT| × (10 nW / °C)] + 10 nW / month

 

500 MHz to 20 GHz

[(100 nW at 25 °C) + |ΔT| × (5 nW / °C)] + 5 nW / month

   Match*3

100 MHz to 250 MHz: 1.18:1 VSWR

(21.7 dB Return Loss)

 

250 MHz to 8 GHz: 1.09:1 VSWR

(23 dB Return Loss)

100 MHz to 250 MHz: 1.18:1 VSWR

(21.7 dB Return Loss)

 

250 MHz to 8 GHz: 1.15:1 VSWR

(27 dB Return Loss)

50 MHz to 10 GHz: 1.20:1 VSWR

(21 dB Return Loss)

 

10 GHz to 18.6 GHz: 1.29:1 VSWR

(18 dB Return Loss)

50 MHz to 10 GHz: 1.20:1 VSWR

(21 dB Return Loss)

 

10 GHz to 20 GHz: 1.29:1 VSWR

(18 dB Return Loss)

   Temperature Uncertainty (T)

40 °C < T ≤ 50 °C: 1.00% (plus 1%, 0 dBm to 10 dBm; plus 3%, 10 dBm to 20 dBm)

 

30 °C < T ≤ 40 °C: 0.75% (plus 1%, 0 dBm to 10 dBm; plus 3%, 10 dBm to 20 dBm)

 

20 °C < T ≤ 30 °C: 0.00%

 

10 °C < T ≤ 20 °C: 0.75% (plus 1%, 0 dBm to 10 dBm; plus 3%, 10 dBm to 20 dBm)

 

0 °C < T ≤ 10 °C: 1.00% (plus 1%, 0 dBm to 10 dBm; plus 3%, 10 dBm to 20 dBm)

40 °C < T ≤ 50 °C: 6.00%

30 °C < T ≤ 40 °C: 3.00%

20 °C < T ≤ 30 °C: 0.00%

10 °C < T ≤ 20 °C: 3.00%

0 °C < T ≤ 10 °C: 6.00%

*1 Total uncertainty includes contributions from Calibration Factor Uncertainty (CF), Linearity Uncertainty (L), Noise Uncertainty (N), Zero Offset Uncertainty (Z), Mismatch Uncertainty, and Temperature Uncertainty (T). All error terms must be converted to percentages for Total Uncertainty (RSS) calculation. Mismatch Uncertainty (Mm) requires knowledge of source match and should be expressed as a percentage using the equation Mm = 100 × [(1 ± Γsource × Γsensor)2 – 1].

*2 Use the following formula to determine Zero Offset Uncertainty as a percentage: Z = (Zero Offset Power / Nominal Power) × 100.

*3Nominal impedance = 50 Ω.

*4Equivalent-time Sampling requires repetitive pulses for accurate results.

General Specifications

Characteristic

Description

Maximum Average Power

+20 dBm (100 mW)

Damage Level: +23 dBm (200 mW)

Maximum Pulse Power

+20 dBm (100 mW)

Damage Level: +23 dBm (200 mW)

Measurement Rate

2000/s (100 settled measurements per second typical)

Trigger In / Trigger Out

TTL compatible

Damage Level: 5.5 V max, –0.5 V min

Rate: 1 Hz to 750 kHz, typical

USB Interface

USB Version: 2.0 Full speed (11 Mb/s)

System Requirements for Meter and High Speed Logger Software

Characteristic

Description

Typical Host Specifications

- 2 GB RAM

- USB 2.0 Port

Operating System

- Windows XP, Service Pack 3

- Windows Vista

- Windows 7 (32-bit, 64-bit, or XP mode)

Environmental

Characteristic

Description

Temperature

   Operating

0 °C to +55 °C

   Nonoperating

–25 °C to +85 °C

Humidity

   Operating

15% to 95% RH (Relative Humidity) at up to +30 °C

15% to 45% RH above +30 °C up to +55 °C; noncondensing

   Nonoperating

15% to 95% RH at up to +30 °C

15% to 45% RH above +30 °C up to +85 °C; noncondensing

Altitude

   Operating

3,000 m (10,000 ft.)

   Nonoperating

15,000 m (50,000 ft.)

Electromagnetic Compatibility

EMC Directive 2004/108/EC, EN 61326-2-1: 2006, CE

Physical Characteristics

Dimension

Description

PSM3110, PSM3120, PSM3310, PSM3320, PSM3510, PSM4320, PSM4410, PSM5320, PSM5410

   Diameter

48 mm (1.9 in.)

   Length

74 mm (2.9 in.), plus connector

PSM4110, PSM4120, PSM5110, PSM5120

   Diameter

48 mm (1.9 in.)

   Length

62 mm (2.4 in.), plus connector

Weight

PSM3110

PSM3310

PSM3510

164 g (5.78 oz.)

PSM3120

PSM3320

203 g (7.16 oz.)

PSM4110

PSM5110

110 g (3.88 oz.)

PSM4120

PSM5120

149 g (5.26 oz.)

PSM4320

PSM5320

163 g (5.75 oz.)

PSM4410

PSM5410

124 g (4.37 oz.)

  • Cam kết chất lượng
  • Bảo hành chính hãng
  • Giao hàng tận nơi
  • Đơn giản hóa giao dịch

Đăng ký nhận bản tin - cơ hội nhận khuyến mãi