For full functionality of this site it is necessary to enable JavaScript.

Ainuo ANFC060T(F) AC Power Supply ANFC Three-phase (60kVA, 90.9A)

Input: 3-phase 4-wires,AC: 380V±57V,50/60Hz±3Hz 
Output Capacity: 60kVA
Frequency Stability:  45.0~65.0H, 100H, 120H, 200H, 240Hz 
Frequency Stability: ≤0.02% 
Output Voltage: 3-phase 4-wires,1.0~300.0V 
Output Current: 90.9A
Line Regulation: ≤1%
Load Regulation: ≤1%
Modulating voltage range: ≤3V
Protection Mode:  IGBT hot、IGBT OverCurrent、Transformer hot、Input Lack Voltage、Input Over Voltage、Output Lack Voltage、Output Over Voltage、Output Over Current、Output Over Power 
Voltage Drop Compensation: 0.000~0.500Ω
Communication:RS232(Standard), RS485(Options), GPIB(Options), Ethernet(Options)    
Remote Control:Analog Control(Options)
Dimension W×H×D(mm): 700*1330*1218
Weight(kg): 480

Details

 

Product Detail

Main features
* Adopt FPGA digital technology,realize precision control and high quality sine wave output;
* Three-phase loading separately,start single phase output by U/V/W fast settings;
* Operating in over current shock(up to 3 time of rated current) within 2s,start the impact load of 1/3 capacity of power supply directly;
* Adjustable voltage and frequency during output status;
* Measurement:voltage,current,frequency,active power;
* Online monitoring:monitor IGBT temperature,transformer temperature,fan speed,input voltage and other parameters during output status;
* Operating data recorders;keep the record of power supply status and alarm code automatically during alarming;
* Voltage rangge:1.0-150.0v or 150.1-300.0v automatic adjustment,or locked at 1.0-300.0v;
* Shortcuts groups,power-off memory,shortcuts key and knobs operation;
* Fan speed will be adjustable automatically with the temoerature of power supply to reduce the noise,;
* Lock key,user-friendly design,automatically locking without operation for 5 minutes to prevent from operation mistakes,;
* Standard RS232,optional RS485,GPIB,Ethernet,analog control and other remote communication/control;

Order and Extensions
* ANFC three-phase AC power supply:1.0-300.0V/45.0-65HZ,100HZ,120HZ,200HZ,240HZ,optional 15KVA,30KVA,45KVA,60KVA,90KVA,120KVA,180KVA,240KVA,Larger capacity can be modified;
* Communication interfaces:Standard RS-232,optional RS485,GPIB,Ethernet,analog control and other remote communication/control.
Larger capacity can be modified;
* Communication interfaces:standard RS-232,optional RS485,GPIB,Ethernet(Remarks:only can select one of RS-232,RS-485,GPIB,Ethernet);
* Remote control interface:optional analog control interface;

* PC control software;

Spec.

Model/Specification

ANFC015 T(F)

ANFC030 T(F)

ANFC045T(F)

ANFC060T(F)

ANFC090T(F)

ANFC120 T(F)

ANFC180 T(F)

Input

3-phase 4-wiresAC 380V±57V50/60Hz±3Hz

Output Capacity

15kVA

30kVA

45kVA

60 kVA

90 kVA

120 kVA

180kVA

Output Frequency

45.0~65.0Hz100Hz120Hz200Hz240Hz

Frequency Stability

≤0.02%

Output Voltage

3-phase 4-wires1.0~300.0V

Output Current

110V

45.4A

90.9A

136.3A

181.8A

272.7A

363.6A

545.4A

220V

22.7A

45.4A

68.2A

90.9A

136.3A

181.8A

272.7A

Accuracy

Voltage

Resolution0.1V

Accuracy0.2%×reading+0.2%×F.S. (45Hz—65Hz)

Current

Resolution0.1A(<1000A)/1A(1000A)

Accuracy0.3%×reading+0.3%×rated output

Frequency

Resolution0.1Hz Accuracy0.05%

Power

Resolution 0.1kW / 0.01kW / 0.001kW

Accuracy 0.45%×reading+0.45%×F.S. (45Hz—65Hz)

Line Regulation

≤1%

Load Regulation

≤1%

Voltage Distortion

Linear load THD1%

Transient time

20ms

Phase retardation

120°+2°

Phase unbalance factor

1%

Crest factor

1.41±0.1

Modulating voltage range

3V

Over Power

105%≤Output110% the output will be stopped within 15 Sec.

110%≤Output210% the output will be stopped within 5 Sec.

210%≤Output310% the output will be stopped within 2 Sec.

310%≤Output410% the output will be stopped within 1 Sec.

410%≤Output the output will be stopped immediately

Protection Mode

IGBT overheatIGBT Over CurrentTransformer overheatInput Lack VoltageInput Over VoltageOutput Lack VoltageOutput Over Voltage、Lack Output Phase Output Over CurrentOutput Over load、Output short Cirluit

Voltage Drop Compensation

0.000~0.500Ω

Softstart Time

0.0~99.9S

Efficiency

86%

Shortcut Group

7 groups

Online Voltage Adjustment

The output voltage and frequency(45-65Hz) can be adjusted online under running status.

Communication/

Remote Control

CommunicationRS232Standard)RS485Options)GPIBOptions)EthernetOptions)

<span style="font-size:9.0pt; font-f

  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information