For full functionality of this site it is necessary to enable JavaScript.

Chauvin Arnoux L481 DC voltage logger (-850 Vdc ~ +850 Vdc)

Manuafacturer: Chauvin Arnoux
Model : L481
Warranty : 12 month

Electrical Specification
- Channels: 1
- Input connection: Two recessed 4 mm safety banana jacks
- Input level: -850 Vdc- +850 Vdc
- Resolution: 0.1 mA
- Accuracy (50/60 Hz)0 to 10 mV: unspecified ; 5 to 50 V: ±(0.5 % R +1 V) – 50 to 850 V: ±(0.5 % R +0.5 V)
- Maximum input voltage: ±1020 Vdc
- Input impedance: > 150 kΩ
- Sample rate: Maximum of 8 per second
- Storage rate: Programmable from 125 ms to 1 day
- Storage modes: Start/Stop, FIFO and Extended Recording Mode (XRM™)
- Recording length: 15 minutes to 8 weeks, programmable using DataView®
- Memory: 240,000 measurement (512 kB). The recorded data is stored in non-volatile memory & retained even if the battery is low or removed
- Communication: USB 2.0 optically isolated
- Power source: 2 x 1.5 V AA-cell alkaline batteries
- Battery life: 100 hours to > 45 days (depending on storage rate/recording length)
Mechanical Specification
- Dimensions: 136 x 70 x 32 mm (5.38 x 2.75 x 1.28")
- Max conductor size: Depends on current probe
- Weight (with battery): 180 g (6.4 oz)
- Casing: UL94-V0
- Vibration: IEC 60068-2-6 (1.5 mm, 10 to 55 Hz)
- Shock: IEC 60068-2-27 (30G)
- Drop:  IEC 60068-2-32 (1 m)
Environment Specification
- Operating temperature: -10 to +50 °C
- Storage temperature: -20 to +60 °C

State at delivery:  delivered with a set of 2 voltage leads 152.4 cm (5 ft) long, with colour coding and a set of crocodile clips (red/black).


Details

datasheet
user guider

Advantages

  • DC voltage logger
  • Detection of intermittent voltage faults
  • Own power supply

Description

The Simple Logger II models automatically adapt their sensitivity (measurement range) and their acquisition rate to optimize recording. It is possible to program alarms or triggers on thresholds or on a predefined range. The LEDs on the front panel enable users to check the status of the logger and the remaining storage capacity at a glance. Compact and battery-powered, the Simple Logger II L481 is easy to position, even in an electrical cabinet.

Specifications:

  • Bipolar voltage logging up to ±850 Vdc
  • Programmable storage rate from 8 per second to 1 per day
  • 3 storage modes as required
  • Storage of up to 240,000 measurements in non-volatile memory
  • Powered by standard alkaline batteries
  • Lightweight and compact, fit anywhere
  • 5 LED indicators for checking the instrument's status at a glance
  • DataView® software supplied FREE with instrument for data storage, real-time waveform display, analysis and report generation
  • Delivered with an isolated USB communication cable and batteries
  • IEC 61010-1  300 V CAT IV and 600 V CAT III
  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information