EBRO EBI 15 Bowie-Dick Logger

Accuricy Temperature: ± 0,1 °C Pressure: ± 15 mbar
Dimensions ø 90 mm x 186 mm
IP Rating IP 68
Measurement temperature, pressure
Measuring range Temperature: 0 °C ... +150 °C Pressure: 0 mbar ... 4.000 mbar
Memory 27.000 measurement values
Operating Temperature 0 °C...+150 °C
Power Supply Lithium 3,6 Volt battery exchangeable
Resolution Temperature: 0,025 °C Pressure: 1 mbar
Sample Rate 1s
Sensor Pt 1000
Details
Registrador de datos Bowie-Dick, campo de medición 0°C ... +150°C / 1 hasta 4000 mbar

Product Description

Technical Data/ EBI 15

 

Measuring range temperature: 0°C ... +150°C

 

Measuring range pressure: 0 mbar ... 4.000 mbar

 

Accuracy: ± 0,1°C / ± 15 mbar

 

Resulution: 0,025°C / 1 mbar

 

Memory: measured values 100.000 valeurs

 

Sensor temperature: Pt 1000

 

Sensor pressure: piezoresistive

 

Channels: 2 temperature, 1 pressure

 

Measuring mode:

 

> endless

 

> start/stop measurement

 

> measurement from start time

 

> start immediately until memory full

 

Measuring rate: 250 ms ... 24 h

 

Battery: 3.6V lithium, exchangeabble

 

Housing: stainless steel V4A, PEEK, PPSU, aluminium

 

Protection clss: IP 68

 

Certificate: according to ISO 9001/2000

 

The data logger EBI 15 is a measuring system for checking steam sterilizers without relying on chemical indicators.

 

This system can check relevant sterilzation parameters such as vacuum, compensation time, hold time and sterilization temperature. Also, steam penetration analogous to a Bowie & Dick Test can be checked.

 

The temperature inside a measuring chamber is compared with the outside temperature. If there is a temperature difference, then this is caused by insufficient steam penetration. On the basis of the temperature difference and of the behaviour of both temperature curves, a statement can be made regarding the cause of the insufficient steam penetration (leakage, insufficient vacuum, air injection).

 

Essentially, here the same method is used as in determining steam penetration with a Helix PCD (process challenge device). Only here, a physical temperature measurement is used instead of a chemical indicator.

 

Winlog.med or Winlog.med Validation automatically evaluates the temperature difference during readout and presents the results (where applicable) with cause of error.

Required Components

 

In order to carry out a routine check with the EBI 15 System, the following components are required:

 

EBI 15 data logger

 

Interface IF 150 (interface IF 100 and IF 200 can also be used, but then the bottom of the EBI 15 must be screwed off before readout)

 

Antenna (for transmission from the steri: steri antenna and throughput)

 

Software Winlog.med