Elcometer FD700DL+ Mini Flaw Detectors (0.01~30480mm, A/B-scan, Thrupaint, datalogging, RS232, Broadband,narrow bands)
Manufacturer: ELCOMETER Model: FD700DL+ - Request a Quotation
- Contact
See more: Equipment Calibration-Inspection & Repair Service
Call for the best priceHanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222)730.39.68
HCM city: (028) 38.119.636
A-Scan display: + Rectified, - Rectified, Full Waveform (RF)
Flaw detection modes: TRIG, DAC, AWS, TCG, Zero Crossing, Flank, Peak
Measurement Mode: PE, PETP (Temp Compensation), EE (ThruPaint™), EEV, CT (Coating) & PECT
Measurement Rate (Thickness Mode)
+ Manual: 4 readings per second
+ Scan mode: 32 readings per second
+ Scan bar display: 6 readings per second
Measuring Range: PE: 0.63 - 30480mm, PETP: 0.63 - 30480mm, EE: 1.27 - 102mm, EEV: 1.27 - 25.4mm, CT: 0.01 - 2.54mm, PECT: 0.63 - 30480mm, PECT: 0.01 - 2.54mm
Measurement Accuracy2: ± 1% or ±0.1mm whichever is the greater
Measurement Resolution: 0.01mm (0.001 inch)
Velocity Calibration Range: 256 - 16,000m/s (0.0100 - 0.6300in/ms)
Data logging: 8,000 with A/B-scan image & gauge settings; 210,000 - coating, material, min, max thickness
Frequency Bands: Broadband 1.8 - 19 MHz, Three narrow bands at 2MHz, 5MHz, 10MHz
Battery Type: 3 x AA alkaline
Battery Life: 12 hours
Size (w x h x d): 63.5 x 165.0 x 31.5mm
Weight (including batteries): 397g (14oz)
Transducer Connector Type: LEMO
RS232 Interface: Bi-directional
Packing List: Elcometer NDT FD700+ or FD700DL+ gauge, couplant, carry case, user manual,
test certificate, 3 x AA batteries, ElcoMaster® software, transfer cable
Note: A transducer is not suppied with the Gauges, must be ordered separately
FD700 Mini Flaw Detectors
The hand-held FD700 flaw detector range combines state-of-the-art flaw detection with advanced material thickness capabilities.
The Elcometer FD700 Mini Flaw Detector is available in two models: FD700+ and FD700DL+.
Whether you are on-site or in the laboratory these gauges are the tool you need for all your flaw detecting needs.
The time corrected gain (TCG) feature automatically compensates for sound attenuation through a material, further increasing the performance of the gauge.
The FD700DL+ stores up to 8,000 readings with A/B-scan images in alpha numeric batches with full data logging via RS232 data output to ElcoMaster® data management software.
Features:
|
FD700 Mini Flaw Detectors
Technical Specification
<td style="border:solid windowtext 1.0pt;mso-borde
Model & Part Number |
FD700+& FD700DL+ |
Material thickness digits display |
■ |
B-Scan cross sectional display |
■ |
B-Scan with digits display |
■ |
Scan bar display |
■ |
Coating thickness display |
■ |
A-Scan display |
+ Rectified, - Rectified, Full Waveform (RF) |
Flaw detection modes |
TRIG, DAC, AWS, TCG, Zero Crossing, Flank, Peak |
Measurement Mode1 |
PE, PETP (Temp Compensation), |
Measurement Rate (Thickness Mode) |
|
Measuring Range2 |
PE: 0.63 - 30480mm (0.025 - 1,200 inches) |
Measurement Accuracy2 |
± 1% or ±0.1mm whichever is the greater |
Measurement Resolution |
0.01mm (0.001 inch) |
Velocity Calibration Range |
256 - 16,000m/s (0.0100 - 0.6300in/ms) |
Additional Features: |
|
High speed scan mode |
■ |
Differential mode |
■ |
Limit alarm mode |
■ |
B-Scan display speed |
adjustable display speed |
Calibration setups |
6 factory & 64 user-definable setups |
Gates |
3 fully adjustable gates: |
Damping |
adjustable; impedance matching for |
Pulser type |
dual 200 Volt square wave pulsers with |
Gain |
manual, automatic gain control (AGC) |
Timing |
precision 25MHz TCXO with single shot |
Data logging |
• 8,000 with A/B-scan image & gauge settings |
Calibration Options |
single, two point, velocity & material type |
Transducer recognition |
automatic |
V-path / dual path error correction |
automatic |
Probe zero |
automatic |
Flaw Detection Mode Features |
|
Automatic |
Longitudinal (straight), |
Probe Types |
Single Contact, Dual, Delay & Angle |
Material Velocity Table |
Contains longitudinal and shear |
TRIG |
Trigonometric display of beam path, |
DAC |
Up to 8 points may be entered and used to digitally |
AWS |
Automatic defect sizing in accordance with AWS |
AVG/DGS |
Automatic defect sizing using probe |
TCG |
Time corrected gain. 50 dB dynamic range, 20 dB |
Detection Modes |
Zero Crossing, Flank and Peak |
Display Freeze |
Hold current waveform on screen |
Peak Memory |
Captures peak signal amplitude. |
PRF |
8 to 2000Hz in selectable steps (8, 16, 32, 66, 125, 250, 333, 1000, 2000Hz) |
Pulse Width |
40 to 400 ns. Selectable step |
Frequency Bands |
FD700+ & FD700DL+: Broadband 1.8 - 19 MHz |
Horizontal Linearity |
+/- 0.4% FSW |
Vertical Linearity |
+/- 1% FSH |
Amplifier Linearity |
+/- 1 dB |
Amplitude Measurement |
0 to 100% FSH, with 1% resolution |
Delay |
0 - 999in (25,375mm) at steel velocity |
Display |
1/4 VGA AMOLED colour display |
Display Refresh Rate |
60 & 120Hz |
Units (selectable) |
mm or inches |
Backlight |
adjustable brightness |
Repeatability / Stability Indicator |
■ |
Battery Type |
3 x AA alkaline |
Battery Life |
12 hours |
Low Battery Indicator |
■ |
Battery Save Mode |
auto |
Size (w x h x d) |
63.5 x 165.0 x 31.5mm |
Weight (including batteries) |
- Quality Engagement
- Easy change and return
- Delivery Avaliable