For full functionality of this site it is necessary to enable JavaScript.

Hioki 9010-50 AC CURRENT SENSOR(10 A to 500 A AC)

- Rated current    10 A to 500 A AC, 6 ranges
- Accuracy    ±2 % rdg. ±1 % f.s. (45 to 66 Hz)
- Frequency characteristics    Add to amplitude accuracy for frequencies from 40 to 1 kHz: ± 6 % rdg. (at 10 A and 20 A range)
± 3 % rdg. (for 50 A range and above)
- Output rate    0.2 V AC f.s. (f.s. = setting rage)
(Connect to a voltage input device providing a high input impedance of 1 MΩ)
- Max. allowable input    150 A rms continuous (10/20/50 A ranges)
400 A rms continuous (100/200 A ranges)
650 A rms continuous (500 A range)
(For 40 Hz to 100 Hz: 100 %, and for 100 Hz to 1 kHz: within 50 % of derating)
- Max. rated voltage to earth    600 Vrms (50/60 Hz, CAT III)
- Core diameter    φ46 mm (1.81 in)
- Dimensions and mass    78 mm (3.07 in)W × 188 mm (7.40 in)H × 35 mm (1.38 in)D, 420 g (14.8 oz), cord length: 3 m (9.84 ft)
- Accessories    Instruction manual ×1

Details

Manual

- Rated current    10 A to 500 A AC, 6 ranges
- Accuracy    ±2 % rdg. ±1 % f.s. (45 to 66 Hz)
- Frequency characteristics    Add to amplitude accuracy for frequencies from 40 to 1 kHz: ± 6 % rdg. (at 10 A and 20 A range)
± 3 % rdg. (for 50 A range and above)
- Output rate    0.2 V AC f.s. (f.s. = setting rage)
(Connect to a voltage input device providing a high input impedance of 1 MΩ)
- Max. allowable input    150 A rms continuous (10/20/50 A ranges)
400 A rms continuous (100/200 A ranges)
650 A rms continuous (500 A range)
(For 40 Hz to 100 Hz: 100 %, and for 100 Hz to 1 kHz: within 50 % of derating)
- Max. rated voltage to earth    600 Vrms (50/60 Hz, CAT III)
- Core diameter    φ46 mm (1.81 in)
- Dimensions and mass    78 mm (3.07 in)W × 188 mm (7.40 in)H × 35 mm (1.38 in)D, 420 g (14.8 oz), cord length: 3 m (9.84 ft)
- Accessories    Instruction manual ×1

  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information