Webtec LT600-FM-S-S-5 Turbine flow meters with frequency output (4-160 US gpm; 5000psi)

Main ports: 1-5/8” -12UN #20 SAE ORB

Top ports: 7/16” -20UN #4 SAE ORB

Flow Range: 4 - 160 US gpm

Maximum pressure: 5000 psi

Functional specification

Ambient temperature: 5 to 40 °C (41 - 104 °F)

Fluid type: Oils, fuels, water glycol, water oil emulsions

Fluid temperature: 5 to 90 °C (41 - 194 °F) continuous use.

Accuracy: 

15 to 100% of range - 1% of indicated reading

Below 15% fixed accuracy of 1% of 15% of full scale

To obtain 1% of indicated readings a Webtec DHCR must be used. Accuracy with other readouts 1% of full scale.

Output: 

Frequency - 20 -2000 Hz

Impedance - 3700 Ohm,

Inductance - 1kHz: 1.55H

Construction material

Flow body: High tensile Aluminium 2014A T6

Internal parts: Aluminium, Steel, Stainless Steel.

Transducer body: Aluminium, Steel - electroless nickel plated, Stainless Steel.

Seals: Viton seals as standard EPDM are available - please consult sales office