For full functionality of this site it is necessary to enable JavaScript.

Ainuo AN96950(F) モーター総合テスター

ACW
+ Out voltage range: 500~3000VAC,10V/step, ±(2.5%×setting+10V)
+ Output frequency: 50/60Hz, ±0.1%×Setting
+ Breakdown current range: 0.100~20.00 mA, ±(2.5%×reading+5 counts)
IR
+ Output voltage range: 500~3000VAC,100V/step; ±5%×setting
+ Energy capatitor:Standard 0.255uH
+ Sampling frequency:50kHz~40MHz,15 adjustemnt range
+ Test time:1~10 times continuous
IW
+ Pulse voltage range: 500~3000VAC,100V/step; ±5%×setting
+ Energy capatitor:Standard 0.022uH
+ Sampling frequency: 50kHz~40MHz,15 adjustment range
DRC
+ Range: 0.020~0.200~2.000~20.00~200.0~2000~20000Ω; ±(0.3%×reading + 3 counts)
Power/Voltage start
+ Voltage range: 20~300V,10V/step; ±(0.3%×reading +0.2%×range)
+ Current range: 0.20~2.00~20.00A; ±(0.3%×reading + 0.2%×range)
+ Active pwer range: 1.0~99.9W~6KW; ±(0.8%×reading +0.2%×range)
+ Frequency range: 45~500Hz; ± 0.1% ×reading
C voltage: 60.0~600.0V; ±0.6%×reading
Speed: 120~99,999rpm; ±0.1%×reading+1
PG single: 
+  PG power:5V or 12V
+ Voltage test:0.50~15.0V; ±(0.5×reading +2 counts)
+ Frequece range:10~1000Hz; ±0.1%×reading+1 count
Rotation: RW/RS/RI/KEEP
Weight: 33 kg

Details

 

 

Product Detail

Main features
* Lock rotor without load: Test lock current and power through non-mechanized V groove,circle bridge,metal board,self-priming return teminals
* Apatitor voltage,value at the same tiem
* Safety test:Static and dynamic leakage current test

Appliction

Suitable for sigle phase multi speed motor,PG motro,Shaded pole motor,Multi speed motor,water pump motor,fan motor,electric tools motor inspection and experiment.


Model

AN96951(F)

AN96950(F)

AN9653(F)

ACW

Out voltage range:500~3000VAC,10V/step.(5000V can be modified)

Voltage accuracy:±2.5%×setting+10V Output frequency:50/60Hz

Frequency accuracy:±0.1%×setting

Breakdown current range:0.100~20.00 mA(100Ma can be modified)

Current accuracy:±2.5%×reading+5 counts

IR

Output voltage range:500~3000VAC,100V/step.(5000V can be modified)

Voltage peak accuracy:±5%×setting

Energy capatitor:Standard 0.255uH,0.047uH is optinal

Front time of impulse:0.5uS

Sampling frequency:50kHz~40MHz,15 adjustemnt range

Test time:1~10 times continuous

Ajustment:Area,differ

IW

Pulse voltage range:500~3000VAC,100V/step.(5000V can be modified)

Voltage peak accuracy:±5%×setting

Energy capatitor:Standard 0.022uH,0.047uH is optinal

Front time of impulse:0.5us

Sampling frequency:50kHz~40MHz,15 adjustment range

Test time:1~10 times continuous

Ajustemnts:Area,differ

DCR

----

Range:0.020~0.200~2.000~20.00~200.0~2000~20000Ω

Accuracy:±0.3%×reading + 3 counts

---

Power/Voltage start

---

Voltage range:

20~300V,10V/step.

Accuracy:±0.3%×reading +0.2%×range

Current range:

0.20~2.00~20.00A

Accuracy:±0.3%×reading + 0.2%×range

Active pwer range:

1.0~99.9W~6KW

Accuracy:±0.8%×reading +0.2%×range

Frequency range:45~500Hz

Accuracy:± 0.1% ×reading

Voltage range:

20~460V,10V/step.

Accuracy:±0.3%×reading +0.2% ×range

Current range:

0.05~6.00~40.00A

(100Ma can be modified)

Accuracy:±0.3%×reading + 0.2% range

Active pwer range:

1.0~99.9W~18kW

Accuracy:±0.8%×reading +0.2×range

Frequency range:45~65Hz

Accuracy:±0.1%×reading

C voltage

---

Voltage range:60.0~600.0V

Accuracy:±0.6%×reading

---

Speed

---

Range:120~99,999rpm

Accuracy:±0.1%×reading+1

---

Rotation

---

RW/RS/RI/KEEP

---

PG single

---

PG power:5V or 12V

Voltage test:0.50~15.0V

Accuracy:±0.5×reading +2 counts

Frequece range:10~1000Hz

Accuracy:±0.1%×reading+1 count

---

Weight(without packaging)

33Kg

 

 