For full functionality of this site it is necessary to enable JavaScript.

Gwinstek GOS-653G アナログオシロスコープ(50MHz、2チャンネル、Delayed Sweep)

The screen display with 8x10 6 inch squares
Sensitivity: 5mV ~ 5V/div±3%,1mV ~ 2mV/div±5%
Bandwidth: 50MHz
InputACDCGND
ModeCH1CH2DUALADD, CH2 INV
Power supply: AC 100V / 120V/220V / 230V ± 10%, 50 / 60Hz
-

CRT
Type 6-inch rectangular type with internal graticule
0%, 10%, 90% and 100% markers.
8 x 10 div (1div=1cm)
Accelerating Potential 12kV
Illumination Continuously adjustable
Z-axis Input
 
Input Impedance: Approx. 5kΩ
Sensitivity:Above 3Vp-p
Bandwidth:DC ~ 5MHz
VERTICAL SYSTEM
Sensitivity 5mV ~ 5V/div±3%,1mV ~ 2mV/div±5%
Bandwidth DC ~ 50MHz
DC ~ 15MHz at 1 ~ 2mV/div
Rise Time 7ns (23.3ns for 1 ~ 2mV/div)
Signal Delay

leading edge can be monitored (GOS-653G only)

Input Impedance Approx. 1MΩ
Input Coupling  AC, DC, GND
Vertical Mode
 
CH1, CH2, DUAL, ADD, CH2 INV
(Dual automatic switching ALT and CHOP)
HORIZONTAL SYSTEM
A(main) Sweep Time 0.1μs ~ 0.5s/div ±3%
100ns ~ 50ms/div ±5% (x 10 MAG)
10ns ~ 50ns ±8% (x 10 MAG)
B(delay) Sweep Time 0.1μs ~ 0.5ms/div ±3%
100ns ~ 50μs/div ±5% (x 10 MAG)
10ns ~ 50ns/div ±8% (x 10 MAG)
Delay Time 1μs ~ 5ms/div ±5% (GOS-653G only)
Delay Time Jitter Better than 1:10000 (GOS-653G only)
TRIGGER
Trigger Mode AUTO, NORM, SINGLE
Trigger Source CH1, CH2, ALT, LINE, EXT
Trigger Coupling AC, DC, HF REJ, TV
Trigger Slope "+" or "-"
X-Y OPERATION
Sensitivity 5mV ~ 5V/div±4%
X-axis Bandwidth DC ~ 2MHz
Phase Error 3° or less from DC ~ 100kHz

OUTPUT SIGNAL

Ch1 Signal Output Voltage: approx. 50mV/div into 50Ω
Calibrator Output 1kHz Square wave, 2Vpp±2%
POWER SOURCE 
  AC 100V/ 120V/ 220V/ 230V ±10%, 50Hz/ 60Hz
DIMENSIONS & WEIGHT 
  310(W) x 150(H) x 455(D) mm; Approx. 8.2kg

Warranty: 12 months
Manufacturer: Gwinstek - Taiwan
Origin: China

Details

 

CRT
Type 6-inch rectangular type with internal graticule
0%, 10%, 90% and 100% markers.
8 x 10 div (1div=1cm)
Accelerating Potential 12kV
Illumination Continuously adjustable
Z-axis Input
 
Input Impedance: Approx. 5kΩ
Sensitivity:Above 3Vp-p
Bandwidth:DC ~ 5MHz
VERTICAL SYSTEM
Sensitivity 5mV ~ 5V/div±3%,1mV ~ 2mV/div±5%
Bandwidth DC ~ 50MHz 
DC ~ 15MHz at 1 ~ 2mV/div
Rise Time 7ns (23.3ns for 1 ~ 2mV/div)
Signal Delay

leading edge can be monitored (GOS-653G only)

Input Impedance Approx. 1MΩ
Input Coupling  AC, DC, GND
Vertical Mode
 
CH1, CH2, DUAL, ADD, CH2 INV
(Dual automatic switching ALT and CHOP)
HORIZONTAL SYSTEM
A(main) Sweep Time 0.1μs ~ 0.5s/div ±3%
100ns ~ 50ms/div ±5% (x 10 MAG)
10ns ~ 50ns ±8% (x 10 MAG)
B(delay) Sweep Time 0.1μs ~ 0.5ms/div ±3% 
100ns ~ 50μs/div ±5% (x 10 MAG) 
10ns ~ 50ns/div ±8% (x 10 MAG)
Delay Time 1μs ~ 5ms/div ±5% (GOS-653G only)
Delay Time Jitter Better than 1:10000 (GOS-653G only)
TRIGGER
Trigger Mode AUTO, NORM, SINGLE
Trigger Source CH1, CH2, ALT, LINE, EXT
Trigger Coupling AC, DC, HF REJ, TV
Trigger Slope "+" or "-"
X-Y OPERATION
Sensitivity 5mV ~ 5V/div±4%
X-axis Bandwidth DC ~ 2MHz
Phase Error 3° or less from DC ~ 100kHz

OUTPUT SIGNAL

Ch1 Signal Output Voltage: approx. 50mV/div into 50Ω
Calibrator Output 1kHz Square wave, 2Vpp±2%
POWER SOURCE 
  AC 100V/ 120V/ 220V/ 230V ±10%, 50Hz/ 60Hz
DIMENSIONS & WEIGHT 
  310(W) x 150(H) x 455(D) mm; Approx. 8.2kg