HANNA HI96734 全塩素、高濃度携帯・携帯光度メーター

  • 生産者:HANNA
    Model: HI96734
    起源: Romania
    品物を保証します: 12 Month
    • 要件クオート Request a Quotation
  • 連絡先
    • カートへ追加
    • 今すぐ注文
  • 校正検証修理サービスを参照してください

      いい価格のため、連絡しなさい

    ホットライン: (+84) 968060220

    電話番号: +84 (24) 62923267

Range Cl, Free 0.00 to 10.00 mg/L
  Cl, Total 0.00 to 10.00 mg/L
Resolution   0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/L
Accuracy @25°C   ±0.03 mg/L ±3% of reading @ 25°C; excluding dilution error
Light Source   tungsten lamp
Light Detector   silicon photocell with narrow band interference filter @ 525 nm
Method   adaptation of the USEPA method 330.5and Standard Method 4500-Cl G
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply   9V battery
Auto-off   after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Dimensions   192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight   360 g (12.7 oz.)
Details
  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features

 

Bleach/chlorine is the most cost effective disinfectant and is used extensively in dialysis clinics. Its use varies from light duty application in surface sanitation to heavy duty disinfection of medical devices or removal of microorganism infections in piping systems. The advantage of chlorine over peroxide type disinfectants is that chlorine not only is a strong oxidant, it also is capable of breaking tough chemical bounds found in cell walls or biofilms. Correct and effective use of bleach/chlorine requires understanding of the chemical nature of the disinfectant.

HI 96734 permits free and total chlorine analysis to monitor overchlorination through chloramine destruction.

The HI 96734 photometer uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.

The cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both the measurement and calibration (zeroing) cuvettes, are optically identical to provide the same measuring conditions.

 

 

Order Information:
HI 96734 is supplied with sample cuvettes with caps (2), battery and instructions.