For full functionality of this site it is necessary to enable JavaScript.

Hioki 3197 パワー品質分析器

- Measurement line type: Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire

- Voltage range: 600.0 V AC

- Current range: 500.0 mA to 5.000 kA AC (depends on current sensor in use)

- Power ranges: 300.0 W to 9.00 MW (depends on combination of current range and line type)

- Basic accuracy

+Voltage: ±0.3 % rdg. ±0.2 % f.s.
+Current: ±0.3 % rdg. ±0.2 % f.s. + current sensor accuracy
+Active power: ±0.3 % rdg. ±0.2 % f.s. + current sensor accuracy (at power factor=1) - - - Measurement items

+ RMS Voltage and Current (200 ms calculation)

+ Voltage (1/2) RMS: one cycle calculation refreshed every half cycle.

+ Current (1/2) RMS: half-cycle calculation.

+ Frequency

+ Active Power/ Reactive Power/ Apparent Power/ Power Factor/ Displacement Power Factor/ Active or Reactive Energy Consumption

+ Demand (Active or Reactive power)

+ Up to 50th Harmonic Analysis (Time series measurement or recording is not capable)

+ Peak Voltage and Current

+ Total harmonic voltage distortion ratio

+ Voltage Unbalance Factor

+ K Factor (Time series recording is not capable)

+ Total harmonic current distortion ratio (Time series recording is not capable)

- Event Detection

+ Voltage Swells (Rise), Voltage Dips (Drop), Interruptions: RMS value detected using voltage (1/2) measured every half cycle

+ Inrush Current: RMS value detected using current (1/2) every half cycle

+ Transient Overvoltage: 50 Vrms or more detection, 10 to 100 kHz

+ Timer: Detect events at preset intervals

+ Manual: Detect events when keys are pressed

Number of Recordable Events: 50 event waveforms, 20 event voltage fluctuation graphs, 1 inrush current graph, 1000 event counts

Interface USB 2.0 (Communication to the PC)

Display: 4.7-inch color STN LCD

Power supply: AC ADAPTER 9418-15 (100 - 240V, 50/60Hz), BATTERY PACK 9459, Continuous use 6 hours (LCD Back-light auto-OFF 5min.), 23VA max.

Dimensions, mass: 128 mm (5.04 in) W × 246 mm (9.69 in) H × 63 mm (2.48 in) D, 1.2 kg (42.3 oz) (with Battery pack)

Supplied accessories: VOLTAGE CORD L9438-55 ×1 (Black×4), AC ADAPTER 9418-15 ×1, BATTERY PACK 9459 ×1, USB Cable ×1, Input Terminal Labels ×1, Input Cord Labels ×1, CD-R (Applications software) ×1, Strap ×1, Carrying case ×1, Measurement guide ×1, Instruction manual ×1

 

Option

CLAMP ON SENSOR 5A 9694x3

CLAMP ON SENSOR 100A 9660x3

CLAMP ON SENSOR 500A 9661x3

FLEXIBLE CLAMP ON SENSOR 5000A CT9667x3

CLAMP ON SENSOR 1000A 9669x3

 

 

Details
Measurement line type Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire
Voltage range 600.0 V AC
Current ranges 500.0 mA to 5.000 kA AC (depends on current sensor in use)
Power ranges 300.0 W to 9.00 MW (depends on combination of current range and line type)
Basic accuracy Voltage: ±0.3 % rdg. ±0.2 % f.s.
Current: ±0.3 % rdg. ±0.2 % f.s. + current sensor accuracy
Active power: ±0.3 % rdg. ±0.2 % f.s. + current sensor accuracy (at power factor=1)
Measurement items
  1. RMS Voltage and Current (200 ms calculation)
  2. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle.
  3. Current (1/2) RMS: half-cycle calculation.
  4. Frequency
  5. Active Power/ Reactive Power/ Apparent Power/ Power Factor/ Displacement Power Factor/ Active or Reactive Energy Consumption
  6. Demand (Active or Reactive power)
  7. Up to 50th Harmonic Analysis (Time series measurement or recording is not capable)
  8. Peak Voltage and Current
  9. Total harmonic voltage distortion ratio
  10. Voltage Unbalance Factor
  11. K Factor (Time series recording is not capable)
  12. Total harmonic current distortion ratio (Time series recording is not capable)
Event Detection
  1. Voltage Swells (Rise), Voltage Dips (Drop), Interruptions: RMS value detected using voltage (1/2) measured every half cycle
  2. Inrush Current: RMS value detected using current (1/2) every half cycle
  3. Transient Overvoltage: 50 Vrms or more detection, 10 to 100 kHz
  4. Timer: Detect events at preset intervals
  5. Manual: Detect events when keys are pressed
Number of Recordable Events 50 event waveforms, 20 event voltage fluctuation graphs, 1 inrush current graph, 1000 event counts
Interface USB 2.0 (Communication to the PC)
Display 4.7-inch color STN LCD
Power supply AC ADAPTER 9418-15 (100 - 240V, 50/60Hz), BATTERY PACK 9459, Continuous use 6 hours (LCD Back-light auto-OFF 5min.), 23VA max.
Dimensions, mass 128 mm (5.04 in) W × 246 mm (9.69 in) H × 63 mm (2.48 in) D, 1.2 kg (42.3 oz) (with Battery pack)
Supplied accessories VOLTAGE CORD L9438-55 ×1 (Black×4), AC ADAPTER 9418-15 ×1, BATTERY PACK 9459 ×1, USB Cable ×1, Input Terminal Labels ×1, Input Cord Labels ×1, CD-R (Applications software) ×1, Strap ×1, Carrying case ×1, Measurement guide ×1, Instruction manual ×1

DOWNLOAD CATALOG

 