Input Functions (Measurement): 

- DC Voltage (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ 50 mV/-5 to 55 mV/1 mV/ 0.02 + 0.02/ Input Resistance : 100MΩ

+ 500 mV/-05 to 550 mV/10 mV/ 0.02 + 0.01/ Input Resistance : 100MΩ

+ 5 V/-0.5 to 5.5 V/ 0.1 mV/ 0.02 + 0.01/ Input Resistance : 1 MΩ

+ 50 V/-5 to 55 V/ 1 mV/ 0.03 + 0.01/ Input Resistance : 1 MΩ

- DC Current (mA)(Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

50 mA/ -5 to 55 mA/ 1 mV/ 0.02% + 0.01/ Shunt Resistance : 10Ω

- Resistance (Ohm) (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ 500Ω Test current; approx. 1 mA/ 0 to 550 Ω/ 0.01 Ω/ 0.05% + 0.02/ Open circuit voltage about 2.5 V

+ 5 KΩ test current; approx. 0.1mA/ 0 to 5.50 KΩ/ 0.1 Ω/ 0.05% + 0.02/ Open circuit voltage about 2.5 V

Frequency (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ 500 Hz/ 3 Hz to 500 Hz/ 0.01 Hz/ ±2 digit/ Input Impedance 100KΩ at least; Sensitivity : 3Vp-p minimum; duty cycle : 50%

+ 5 KHz/ 3 Hz to 5 KHz/ 0.1 Hz/ ±2 digit/ Input Impedance 100KΩ at least; Sensitivity : 3Vp-p minimum; duty cycle : 50%

+ 50 KHz/ 3 Hz to 50 KHz/ 1 Hz/ ±2 digit/ Input Impedance 100KΩ at least; Sensitivity : 3Vp-p minimum; duty cycle : 50%

Thermocouples (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ R/ 0 to 1767°C/ 1°C/ 0 to 500°C : 1.8°C/ By using ITS-90 temperature scale

+ S/ 0 to 1767°C/ 1°C/ 500 to 1767°C : 1.5°C/ By using ITS-90 temperature scale

+ K/ -100 to 1372°C/ 0.1°C/ -100 to 0°C : 1.2°C; 0 to 1372°C : 0.8°C/ By using ITS-90 temperature scale

+ E/ -50 to 1000°C/ 0.1°C/ -50 to 0°C : 0.9°C; 0 to 1000°C : 1.5°C/ By using ITS-90 temperature scale

+ J/ -60 to 1200°C/ -60 to 0°C : 1°C; 0 to 1200°C : 0.7°C/ By using ITS-90 temperature scale

+ T/ -100 to 400°C/ 0.1°C/ -100 to 0°C : 1°C; 0 to 400°C : 0.7°C/ By using ITS-90 temperature scale

+ N/ -200 to 1300°C/ 0.1°C/ -200 to 0°C : 1.5°C; 0 to 1300°C : 0.9°C/ By using ITS-90 temperature scale

+ B/ 600 to 1820°C/ 1°C/ 600 to 800°C : 2.2°C; 800 to 1000°C : 1.8°C; 1000 to 1820°C : 1.4°C/ By using ITS-90 temperature scale

-RTD (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ Pt100 385/ -200 to 800°C/ 0.1°C/ -200 to 0°C : 0.5°C; 0 to 400°C : 0.7°C; 400 to 800°C : 0.8°C/ By using Pt100-385 does not include lead resistance

+ Pt1000 385/ -200 to 630°C/ 0.1°C/ -200 to 100°C : 0.3°C; 100 to 300°C : 0.5°C; 300 to 630°C : 0.7°C/ By using Pt100-385 does not include lead resistance

+ Pt200 385/ -200 to 630°C/ 0.1°C/ -200 to 100°C : 0.8°C; 100 to 300°C : 0.9°C; 300 to 630°C : 1.0°C/ By using Pt100-385 does not include lead resistance

+ Pt500 385/ -200 to 630°C/ 0.1°C/ -200 to 100°C : 0.4°C; 100 to 300°C : 0.5°C; 300 to 630°C : 0.7°C/ By using Pt100-385 does not include lead resistance

+ Cu10/ -100 to 260°C/ 0.1°C/ 1.8°C/ By using Pt100-385 does not include lead resistance

+ Cu50/ -50 to 150°C/ 0.1°C/ 0.7°C/ By using Pt100-385 does not include lead resistance

Switch (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

_/ Close / open/ _/ _/ Approx.. 1 mA test current. Short circuit display “Close Open” : OPEN Threshold value about 200 to 300Ω

Continuity (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

500Ω/ <50Ω sound/_/ _/Approx. 1 mA test current

Output Functions (Simulation): 

- DC Voltage (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ 100 mV/-10 to 110 mV/1 mV/ 0.02 + 0.01/ Max output current 5 mA

+ 1 V/-0.1 to 1.10 V/10 mV/ 0.02 + 0.01/ Max output current 2 mA

+ 10 V/-1 to 11 V/0.1 mV/ 0.02 + 0.01/ Max output current 5 mA

- DC Current (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

20 mA/ 0 to 22 mA/ 1 mA/ 0.02 + 0.02/ External supply for simulate mA : 5V – 28V. Max. load 1KΩ at 20mA

- Resistance (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ 400Ω/ 0 to 400Ω/ 0.01Ω/ 0.02 + 0.02/ Excitation current : ±0.5 – 3mA; if ±0.1 – 0.5 add 0.1Ω Accuracy does not include lead resistance

+ 4KΩ/ 0 to 4KΩ/ 0.1Ω/ 0.05 + 0.025/ Excitation current : ±0.05 – 0.3mA; does not include lead resistance.

+ 40KΩ/ 0 to 40KΩ/ 1Ω/ 0.1 + 0.1/ Excitation current : ±0.01mA; does not include lead resistance.

- Thermocouple (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ R/ 0 to 1767°C/ 1°C/ 0 to 100°C:1.5°C; 100 to 1767°C : 1.2°C/ By using ITS-90 temperature scale, the accuracy does not include the error internal temperature compensation caused by a sensor.

+ S/ 0 to 1767°C/ 1°C/ 0 to 100°C : 1.5°C; 100 to 1767°C : 1.2°C/ By using ITS-90 temperature scale, the accuracy does not include the error internal temperature compensation caused by a sensor.

+ K/ -200 to 1372°C/ 1°C/ -200 to -100°C : 0.6°C; -100 to 400°C : 0.5°C; 400 to 1200°C : 0.7°C; 1200 to 1372°C : 0.9°C/ By using ITS-90 temperature scale, the accuracy does not include the error internal temperature compensation caused by a sensor.

+ E/ -200 to 1000°C/ 1°C/ -200 to -100°C : 0.6°C; -100 to 600°C : 0.5°C; 600 to 1000°C : 0.4°C/ By using ITS-90 temperature scale, the accuracy does not include the error internal temperature compensation caused by a sensor.

+ J/ -200 to 1200°C/ 1°C/ -200 to -100°C : 0.6°C; -100 to 800°C : 0.5°C; 800 to 1200°C : 0.7°C/ By using ITS-90 temperature scale, the accuracy does not include the error internal temperature compensation caused by a sensor.

+ T/ -250 to 400°C/ 1°C/ -250 to 400°C : 0.6°C/ By using ITS-90 temperature scale, the accuracy does not include the error internal temperature compensation caused by a sensor.

+ N/ -200 to 1300°C/ 1°C/ -200 to -100°C : 1°C; -100 to 900°C : 0.7°C; 900 to 1300°C : 0.8°C/ By using ITS-90 temperature scale, the accuracy does not include the error internal temperature compensation caused by a sensor.

+ B/ 600 to 1820°C/ 1°C/ 400 to 800°C : 2°C; 900 to 1300°C : 0.8°C/ By using ITS-90 temperature scale, the accuracy does not include the error internal temperature compensation caused by a sensor.

- RTD (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ Pt100 385/ -200 to 800°C/ 0.1°C/ -200 to 0°C : 0.3°C; 0 to 400°C : 0.5°C; 400 to 800°C : 0.8°C/ Excitation Current : ±0.5 to ±3 mA 

+ Pt1000 385/ -200 to 630°C/ 0.1°C/ -200 to 100°C : 0.2°C; 100 to 300°C : 0.5°C; 300 to 630°C : 0.7°C/ Excitation Current : ±0.05 to ±0.3mA

+ Pt200 385/ -200 to 630°C/ 0.1°C/ -200 to 100°C : 0.8°C; 100 to 300°C : 0.9°C; 300 to 630°C : 1.0°C/ Excitation Current : ±0.05 to ±0.3mA

+ Pt500 385/ -200 to 630°C/ 0.1°C/ -200 to 100°C : 0.4°C; 100 to 300°C : 0.5°C; 300 to 630°C : 0.7°C/ Excitation Current : ±0.05 to ±0.3mA

+ Cu10/ -100 to 260°C/ 0.1°C/ 1.8°C/ Excitation Current : ±0.5 to ±3 mA 

+ Cu50/ -50 to 150°C/ 0.1°C/ 0.7°C/ Excitation Current : ±0.5 to ±3 mA 

Frequency (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ 100 Hz/ 1 to 110 Hz/ 0.01 Hz/ ±2 count/ Output voltage : +1 to 11 Vp-p (zero base waveform); Amplitude Accuracy :±(5% +0.5V); Maximum load : >100KΩ; Duty cycle : 50%

+ 1 KHz/ 0.100 to 1.100 KHz/ 1 Hz/ ±2 count/ Output voltage : +1 to 11 Vp-p (zero base waveform); Amplitude Accuracy :±(5% +0.5V); Maximum load : >100KΩ; Duty cycle : 50%

+ 10 KHz/ 1 to 11 KHz/ 0.1 KHz/ ±2 count/ Output voltage : +1 to 11 Vp-p (zero base waveform); Amplitude Accuracy :±(5% +0.5V); Maximum load : >100KΩ; Duty cycle : 50%

+ 100 KHz/ 10 to 110 KHz/ 2 KHz/ ±5 count/ Output voltage : +1 to 11 Vp-p (zero base waveform); Amplitude Accuracy :±(5% +0.5V); Maximum load : >100KΩ; Duty cycle : 50%

- Pulse (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ 100 Hz/ 1 to 100000 cycles/ 1 cycle/ ±2 count/ Output voltage : +1 to 11 Vp-p (zero base waveform); Amplitude Accuracy :±(5% +0.5V); Maximum load : >100KΩ; Duty cycle : 50%

+ 1 KHz/ 1 to 100000 cycles/ 1 cycle/ ±2 count/ Output voltage : +1 to 11 Vp-p (zero base waveform); Amplitude Accuracy :±(5% +0.5V); Maximum load : >100KΩ; Duty cycle : 50%

+ 10 KHz/ 1 to 100000 cycles/ 1 cycle/ ±2 count/ Output voltage : +1 to 11 Vp-p (zero base waveform); Amplitude Accuracy :±(5% +0.5V); Maximum load : >100KΩ; Duty cycle : 50%

- Switch (Reference/ Ranges/ Resolution/ Accuracy/ Remarks):

+ 100 Hz/1 Hz to 110 Hz/ 0.01 Hz/ ±2 count/ FET Switch maximum open/close Voltage : +28V; Max. open/close; Current : 50mA

+ 1 KHz/0.100 KHz to 1.100 KHz/ 1 Hz/ ±2 count/ FET Switch maximum open/close Voltage : +28V; Max. open/close; Current : 50mA

+ 10 KHz/1 KHz to 11 KHz/ 0.1 KHz

+ 100 KHz/ 10 KHz to 110 KHz/ 2 KHz/ ±5 count


Standard delivery:

Multifunction Process Calibrator – Nagman 25

5V x 4 Nos. AAA Alkaline Batteries

Operation Manual

Test Leads

Traceable Calibration Certificate

Optionals:

Calibration Certificate from NABL Accredited –as per ISO/IEC 17025:2005 Laboratory 

Details

Datasheet