PCE HDM 20 デジタルマルチメーター
生産者: PCE Model: HDM 20 起源: China 品物を保証します: 12 Month - 要件クオート
- 連絡先
Specifications
Display: Colour TFT, 6000 points with status display
Conversion: TRMS
Reference standards: IEC/EN61010-1, IEC/EN61326-1
Isolation: Double
Pollution degree: 2
Overload category: CAT IV 600 V, CAT III 1000 V
Battery type: 1 x 7.4V Li-Ion battery, 2300-mAh
Power supply charger: 100 / 240V AC, 50/60 Hz, 10V DC, 1 A
Battery level indicator: Yes
Automatic shutdown: After 15, 30 or 60 minutes of inactivity (deactivatable)
Fuses: F10A/1000V, 10 x 38 mm (Input 10 A); F800mA/1000V, 6 x 32 mm (Input mA, µA)
Test temperature: 18 ... 28°C / 64 ... 82°F
Operating conditions: 5 ... 40°C / 41 ... 104°F, <80% r.H.
Storage conditions: -20 ... 60°C / -4 ... 140°F, <80% r.H.
Maximum operating height: 2000 m / 2187 yd
Dimensions: 175 x 85 x 55 mm / 6.9 x 3.3 x 2.1 in
Weight: 540 g / 1 lb 3oz
Technical Data DC Voltage
Measuring range Resolution; Measurement accuracy; Input resistance; Overload protection
600 mV; 0.1 mV; ± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms
6V; 0.001V;± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms
60V; 0.01V; ± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms
600V; 0.1V; ± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms
1000V; 1V; ± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms
Technical Data AC Voltage (TRMS)
Measuring range Resolution; Measurement accuracy
(50 ... 60 Hz); Measurement accuracy
(61 Hz ... 1 kHz); Overload protection
6V; 0.001V; ± (0.8% of measurement value +5 Dgt)±;
(2.4% of measurement value +5 Dgt); 1000V DC / ACrms
60V; 0.01V; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms
600V; 0.1V; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms
1000V; 1V; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms
Technical Data DC and AC voltage (TRMS)
Measuring range Resolution; Measurement accuracy; Input resistance; Overload protection
6V; 0.001V; ± (2.4% of measurement value +20 Dgt); >10 MΩ; 1000V DC / ACrms
60V; 0.01V; ± (2.4% of measurement value +20 Dgt); >10 MΩ; 1000V DC / ACrms
600V; 0.1V; ± (2.4% of measurement value +20 Dgt); >10 MΩ 1000V DC / ACrms
1000V; 1V; ± (2.4% of measurement value +20 Dgt); >10 MΩ ;1000V DC / ACrms
Technical Data Direct Current
Measuring range Resolution; Measurement accuracy; Overload protection
600 µA; 0.1µA; ± (0.9% of measurement value +5 Dgt); Protection 800-mA / 1000 V
6000 µA 1 µA; ± (0.9% of measurement value +5 Dgt); Protection 800-mA / 1000V
60-mA; 0.01-mA ± (0.9% of measurement value +5 Dgt); Protection 800-mA / 1000V
600-mA; 0.1-mA ± (0.9% of measurement value +8 Dgt); Protection 800-mA / 1000V
10 A; 0.01 A ± (1.5% of measurement value +5 Dgt); Protection 10 A / 1000V
Technical Data Alternating Current (TRMS)
Measuring range Resolution; Measurement accuracy; Overload protection
600 µA; 0.1 µA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V
6000 µA; 1 µA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V
60-mA; 0.01-mA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V
600-mA; 0.1-mA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V
10 A; 0.01 A; ± (1.5% of measurement value +5 Dgt); Protection 10 A / 1000V
Technical Data Coil Current
Measuring range Resolution; Measurement accuracy
(50 ... 60 Hz); Measurement accuracy (61 Hz ... 1 kHz); Overload protection
30 A; 0.01 A; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms
300 A; 0.1 A; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms
3000 A 1 A; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms
Technical Data Diode Test
Test current: <1.5-mA
Maximum voltage at the open circuit: 3.3V DC
Resistance and continuity test
Measuring range Resolution; Measurement accuracy; Acoustic warning sound; Overload protection
600 Ω; 0.1Ω; ± (0.5% of measurement value +10 Dgt); >50 Ω; 1000V DC / ACrms
6 Ω; 0.001 kΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms
60 kΩ; 0.01 kΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms
600 kΩ; 0.1 kΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms
6 MΩ; 0.001 MΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms
60 MΩ; 0.01 MΩ; ± (2.5% of measurement value +10 Dgt); >50 Ω; 1000V DC / ACrms
Technical Data Frequency
Measuring range; Resolution;
Measurement accuracy; Overload protection
40 Hz ... 10 kHz; 0.01 Hz ... 0.001 kHz; ± (0.5% of measurement value); 1000V DC / ACrms
60 Hz; 0.01 Hz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms
600 Hz; 0.1 Hz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms
6 kHz; 0.001kHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms
60 kHz; 0.01kHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms
600 kHz; 0.1 kHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms
6 MHz; 0.001 MHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms
10 MHz; 0.01 MHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms
Technical Data Duty Cycle
Measuring range; Resolution; Measurement accuracy; Overload protection
60 nF; 0.01 nF; ± (1.5% of measurement value +20 Dgt); 1000V DC / ACrms
600 nF; 0.1 nF; ± (1.2% of measurement value +8 Dgt); 1000V DC / ACrms
6 µF; 0.001 µF; ± (1.5% of measurement value +8 Dgt); 1000V DC / ACrms
60 µF; 0.01 µF; ± (1.2% of measurement value +8 Dgt); 1000V DC / ACrms
600 µF; 0.1 µF; ± (1.5% of measurement value +8 Dgt); 1000V DC / ACrms
6000 µF; 1 µF; ± (2.5% of measurement value +20 Dgt); 1000V DC / ACrms
Technical Data Temperature (Thermoelement Type K)
Measuring range; Resolution
Measurement accuracy; Overload protection
-40 ... 600°C / -40 ... 1112°F; 0.1°C / 0.18°F; ± (1.5% of measurement value 3°C / 5.4°F); 1000V DC / ACrms
600 ... 1000°C / 1112°F ... 1832°F; 1°C / 1.8°F ± (1.5% of measurement value 3°C / 5.4°F); 1000V DC / ACrms
Dilivery Contents
1 x Multimeter PCE-HDM 20
2 x Measurement line
1 x Type K Type K thermocouple probe
2 x Li-ion battery
1 x Charger
1 x Power plug
3 x Attachment for power plug
1 x Micro-SD Card (8 GB)
1 x Magnet
1 x Fabric loop
1 x Temperature adapter
1 x User manual
- 良質な取り決め
- オリジナル保証
- 宅配便
- 買い取り簡単化