For full functionality of this site it is necessary to enable JavaScript.

Powertek MC142 多機能キャリブレータ15 ppm

Manufacturer: Powertek
Model: MC142

Details

 

  Datasheet

mc140-mc142-accessories

Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required.  It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency.  Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors.  Its built-in multimeter can be used independently or simultaneously with the calibrator output.  Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

 


MC142 multifunction calibrator is available
 as bench-top or 19" rack housing

 

 

Basic parameters

Basic function of the calibrator is the generation of calibrated DC/AC voltage in the range from 0µV to 1000V and DC/AC current in the range from 0 to 30A. Using a 50-turn coil the current range can be extended to 1500A. The best accuracy of the calibrator on DC voltage ranges is 15ppm, on AC voltage ranges 250ppm, on DC current ranges 130ppm and on AC current ranges 550ppm. Maximum frequency range is from 20Hz to 100kHz for harmonic output waveform. The calibrator is equipped with a function generator for periodic non-harmonic signals with defined crest factor, making it possible to test sensitivity of multimeters to distorted signals.  In addition the calibrator simulates resistance and capacitance,  the resistance range from 0.0 Ohm to 1000MOhm and capacitance from 1nF to 100µF can be simulated exceeding  the required precision for calibration of common hand-held multimeters. Basic accuracies are resistance ranges 150ppm and capacitance ranges 0.1%.

Frequency function of the calibrator makes it possible to generate a square wave signal with adjustable and calibrated duty ratio, frequency and amplitude in range from 1mV to 10V in the frequency band up to 10kHz. In the mode HF the square wave signal up to 20MHz with a very low rise-time can be generated. The frequency functions are suitable for the calibrations of corresponding frequency ranges of the multimeters and for calibration of the channel sensitivities and time bases of the oscilloscopes as well.

For calibrations of DC and one-phase AC power-meters and energy meters, the power – energy mode is determined. Output voltage can be set up to 240V and output current up to 20A with the power factor in range from -1 to +1 in the frequency band from 40Hz to 400Hz. Current capability of the voltage output is 30mA. It allows calibration of analogue power-meters which have higher current draw. For calibrations of the thermometers and temperature regulators, the function of simulation of temperature sensors is determined. Calibrator is able to simulate all common used Pt and Ni resistance sensors and TC sensors of the R, S, B, J, T, E, K and N types as well. Compensation of the TC cold junction is made either by entering value from the keyboard, or automatically by measuring the ambient temperature with Pt-100 sensor. The precision of the simulated resistance and TC sensors depends on set value and type of the sensor. For resistance sensors uncertainty band is in the range from 0.04°C to 0.5°C, for TC sensors from 0.4°C to 4.0°C.

Built-in multimeter

The MC142 internal multimeter has a basic capability to measure DC current to 20mA, DC voltage to 10V, resistance to 2kOhm and frequency to 15kHz as standard. With accuracy of 100ppm it enables measurement of output signals of various types of transducers. With external TC or resistance temperature sensors, temperature can be scaled, as can  external strain gauge sensors, for pressure, torsion, strength, etc. actual units can be measured and displayed.
 

Calibrator – Tester

Calibrator can be used in simultaneous mode, i.e. selected output signal is generated and the response of the device under test is measured at the same time by internal multimeter. Programmable capability of the calibrator enables setting of 10 steps defined by output signal function and output value on source side and awaiting response of DUT measured by internal multimeter including allowed limits of the DUT. The testing can run automatically.
 

Ease of use

MC142 Calibrator is equipped with a number of other functions which make its use easier. Among them belong possibility to set relative deviations from the actual value of the selected output signal, displaying of the output signal uncertainty, internal calibration procedure and others. Concept of the calibrator control and indication uses a large area luminescence display on which all necessary information is concentrated. The control is perform by selection from the menu. Moreover, frequently used functions have firmly assigned keys with direct control. Normally, the calibrator is equipped with the GPIB bus and with the RS-232 serial port making it possible to be controlled by personal computer.

The calibrator can be included into POWERTEK WinQbase/CALIBER software calibration systems.

MC142 calibrator is derived from previous successful model MC-140. Against MC-140 model the new MC142 offers extended ranges and higher accuracy.

Specifications


DC/AC voltage sine output

Voltage range: 

0 to 1000V

Frequency range:  

20Hz to 100kHz

Resolution:   

6½ dig.

 

Range

% of value + uV

% of value + uV

% of value + uV

% of value + uV

 

DC

20Hz - 10kHz

10kHz - 50kHz

50kHz - 100kHz

0mV - 20mV

0.005 + 6

0.2 + 30

0.20 + 30

1.0 + 30

20mV - 200mV

0.0015 + 8

0.1 + 80

0.15 + 120

0.3 + 120

200mV - 2V

0.0012 + 10

0.018 + 100

0.05 + 200

0.2 + 1000

2V - 20V

0.0010 +50

0.018 + 1000

0.05 + 6000

0.2 + 10000

20V - 240V

0.0015 + 500

0.018 + 10m

- -

- -

240V - 1000V

0.005 + 20000

0.03 + 200m*

- -

- -

 

 

DC/AC current sine output

Current range: 

0 to 30A

Frequency range:

20Hz to 10kHz

Resolution Setting:

6½ dig.

  

 

<td style="border:inset lightgrey 1.0pt;mso-border-alt:inset lightgrey .75pt;

Range

% of value + µA

% of value + µA

% of value + µA

% of value + µA

 

DC

20Hz - 1kHz

1kHz - 5kHz

5kHz - 10kHz

1µA - 200µA

0.05 + 0.02 

 0.15 + 0.02

0.30 +0.22

- -

200µA - 2mA

0.02 + 0.1 

0.07 + 0.2

0.20 + 1

0.50 + 1.4

2mA - 20mA

0.01 + 0.6