For full functionality of this site it is necessary to enable JavaScript.

YSI 5200A マルチパラメータ監視及び制御器

Specifications:

- Buffer Recognition: Yes
- Certifications: RoHS, IP-65, ETL, CUL, NEMA 4X, CE, Made in USA, ULC
- Connectivity / Communications: Ethernet and wireless optional.
- Output Relays: 4 each 10 amp 115 VAC (5 amp 230 VAC) relays for parameter, control and/or
alarm E-mail and/or SMS alarming up to 3 e-mails with Ethernet module or up to 10 e-mails with AquaMana, RS-485 and RS-232 standard
- Data Management: AquaManager™ Software integrates process control, alarming, and data management into one product
- Desktop Software Compatible: Windows 2000/XP/Vista/Windows 7 operating systems, AquaManager®
- Display: Back-lit graphic LCD (320 x 240) with timer, extended temperature range LCD
- Equipment used with: or 30, 10, 5561-4, 20, or 20, AquaManager Desktop Software, 5562-4
- GLP Compliance: Yes
- Logging Capabilities: Yes
- Measurement Method / Channels: DO, pH, ORP, conductivity, temperature, 2 user-configurable inputs,
digital (0 to 1.0 VDC, 0 to 5.0 VDC or 4-20 mA) Timers: 4 timers - 10 events cascading events start/duration
1 feed timer channel (feeder not included), Feed Smart software manages feed
- Memory: Non-volatile, 1000 data, 1250 relay/alarm, 1000 entries/change and 500 GLP records
- Monitoring: Yes
- Multiparameter: Yes
- Operating Temperature: -15 to +70°C (5 to 158°F), direct outside conditions with NEMA 4X enclosure
- Parameters Measured: Dissolved Oxygen (electrochemical), pH,ORP/Redox, Conductivity, Specific Conductance, Salinity, Total Dissolved Solids (TDS), Temperature
- Power: 12 V DC, mobile live haul or anytime AC power not available
- User Calibratable: Yes
- User Replaceable: Yes
- Waterproof: Yes

Parameter (unit) Range Accuracy Resolution
Dissolved Oxygen*
(% saturation)
0 to 500% 0 to 200%: ±2% or ±0.2 mg/L, whichever is greater;
200 to 500%: ±6% of reading
0.1% air saturation
Dissolved Oxygen*
(mg/L, ppm)
0 to 60 mg/L 0 to 20 mg/L: ± 0.2 mg/L or ±2% of reading, whichever is greater;
20 to 60 mg/L: ±6% of reading
0 to 10 mg/L: 0.01 mg/L 
10 – 60 mg/L: 0.1 mg/L
Temperature
(°C, °F)
0 to +45°C (32 to 113°F) ±0.2°C 0.1°C
Conductivity
(µS, mS)
0 to 200 µS;
0 to 2000 µS
0 to 20 mS;
0 to 200 mS
0 to 100 mS: ±0.5% of range​
100 to 200 mS: ±1.0% of reading
0.1 µS
1 µS
0.01 mS
0.1 mS
(range dependent)
Salinity
(ppt)
0 to 80 ppt (0 to 50 ppt when entered manually) ±2% or ±0.1 ppt,
whichever is greater
0.1 ppt​
pH
(pH units)
0 to 14 units ±0.2 units 0.01 units
ORP
(mV)
-2000 to +2000 mV ±20 mV 1 mV
Details

YSI Aquaculture Continuous Monitoring and Control | W24-04
6-Series, 556 & 5200 Probe Installation Guide
YSI 5200A User Manual

Accessories
- Zobell Solution, ORP Calibrator
- pH Buffer
- Conductivity Calibrator Solution
- 5578 12-Volt Power Supply, 230 VAC Input
- 5579 12-Volt Power Supply, 115 VAC Input
- 6505 Weather Shield
- 6509 Rail Mount Kit
- 6510 Panel Mount Kit
- Cap Membrane Kit 2.00 Mil PE
- 5561 Polarographic DO and Temperature Cable
- 5562 Polarographic DO, Temperature, and Conductivity Cable
- pH Kit
- pH/ORP Kit
- AquaManager® Software
- Internal Serial to Ethernet Device Kit
- REM-4 Relay Expansion Module
- IOEM Input, Output Expansion Module

  • 良質な取り決め
  • オリジナル保証
  • 宅配便
  • 買い取り簡単化

おまけチャンス‐ニュースを受ける登録