Ainuo AN9651F (F) 전기 안전 종합 테스터 (AC 전원 공급 장치 (5KW) 내장)

1) AC Hipot test
Booster rated output capacity: 500VA(5000V/100mA)
Booster maximum short-circuit current: >200mA
Output waveform: Sine wave
Output voltage setting:  500~5000V ± 3%
Frequency setting: 50Hz/60Hz ±0.1% 
Current upper-limit:  0.10~99.99mA 
Current lower-limit:  0.00~10.00mA 
Compensation current : 0.00~10.00mA
Time setting:  1~999s 
2) Insulation Resistance test
Rated output capacity: 2VA(1000V/2mA)
Output voltage setting: DC 500Vor1000V
Resistance upper-limit range: 0.0~99.9 MΩ,100~2000MΩ
Resistance lower-limit range:  0.3~99.9 MΩ, 100~2000MΩ 
Insulation resistance measurement:  0.0~99.9 MΩ, 100~2000 MΩ 
3) Ground Bond Resistance test
Output current setting:  3~30A 
Current frequency setting: Sine waveform 50Hz/60Hz
4) Leakage Current test
Current upper-limit range:  0.050~9.999mA 
Current lower-limit:  0.000~5.000mA 
Leakage current compensation setting: 0.000~1.000mA
Leakage current measurement: 0.050~9.999mA 
Output voltage measurement: 60~280V
Dimension (WxHxD): 483x600x1355
Gross weight: 80 kg           

Details

 

Product Detail

Main features
* Comply with CCC,IEC EN,VED,BS,UL,JIS standard requiements.
* Latest international standard:500VA AC Hipot capacity(AC 5KV/100mA),short-circuit output current exceeds 200mA.Built-in optional leakage current test network MD card,meeting requirements of different industrial standards Maximum test current of Ground Bond resistance is up to 64A
*6 in 1:AC Hipot,Insulation Resistance,Ground Bond resistance,Leakage Current,Running Power,Low-Voltage Start.
Standby power consumption is optional for AN9651F(F)and AN9651S(F),minimum is low to 0.50w,accuracy is 0.2%
* Simple operation:LED backlit screen display.menu operation,Chiense/English langues,socket test fixture.
* Flexible configuration:Built in isolated transformer,AC frequency conversion power supply,frequency conversion power supply and industrial PC combiantion

* Satisfy lattest requirements:Follow the production line developing trends of comprehensive,fast,automation and information.Satisfy quality management,5s management and refid management requirements.

AC Hipot test

 

Booster rated output capacity

500VA5000V/100mA

 

Booster maximum short-circuit current

>200mA

 

Output waveform

Sine wave, <3%pure resistance5000V/1mA),<3%From empty load to full load

 
 

Output voltage setting

Range

5005000V

 

Resolution

5V

 

Accuracy

±3%×setting+10V

 

Frequency setting

Range

50Hz/60Hz

 

Accuracy

±0.1%×setting

 

Alarming limits setting

Current upper-limit

0.1099.99mA

 

Current lower-limit

0.0010.00mA

 

Compensation current setting

Range

0.0010.00mA, automatic testing, compensation can be set to ON/OFF

 

Time setting

Range

1999s

 

Ramp up time range

1100s

 

Accuracy

±0.1%×setting+1count

 

Breakdown current alarm

Range

0.1099.99mA

 

Accuracy

±3%×reading+3counts

 

Insulation Resistance test

 

Rated output capacity

2VA1000V/2mA

 

Output voltage regulation

<3%From no load to full load

 

Output voltage ripple

<1%

 

Output voltage setting

Range

DC 500Vor1000V

 

Accuracy

±3%×setting+3counts

 

Alarming limits setting

Resistance upper-limit range

0.099.9 MΩ1002000MΩIf upper-limit is set to 0, it will not make adjudgment for upper limit

 

Resistance lower-limit range

0.399.9 MΩ, 1002000MΩ

 

Time setting

Range

1999s

 

Accuracy

±0.1%×setting+1count

 

Insulation resistance measurement

Range

0.099.9 MΩ, 1002000 MΩ

 

Accuracy

≤200MΩ: ±3%×reading+3counts

 

200MΩ:±8%×reading+8counts

 

Ground Bond Resistance test

 

No load output voltage

<12v span="">

 

Output current setting

Range

330A

 

Accuracy

±3%×setting+0.2A

 

Current range instruction

Optional: 3 ~ 64A test current

 

Current frequency setting

Range

Sine waveform 50Hz/60Hz

 

Accuracy

±0.1%×setting

 

Test time setting

Range

1999s

 

Accuracy

±0.1%×setting+1count

 

Result display mode

Ground resistance or voltage

 

Ground resistance display mode

 

Alarming limits setting

Resistance upper-limit range

3A≤output current≤10A:10600 mΩ

 
 
 

Resistance lower-limit range

0100 mΩ

 

Compensation resistance setting

Range

0200 mΩ, automatic testing, compensation can be set to ON/OFF

 

Ground bond resistance measurement

Range

10600 mΩ

 

Accuracy

±3%×reading+