For full functionality of this site it is necessary to enable JavaScript.

PCE HDM 20-ICA 헤비 듀티 산업용 멀티 미터

- Temperature measurement with thermal imaging camera:  

Sampling rate: 3 times per second

Field of view (FOV): 21° x 21°C / 0.5 m / 1 ft 7.6"

Spatial resolution (IFOV): 4.53 mrad

Resolution infrared camera: 80 x 80 Pixel

Thermal sensitivity / NETD: <0.1°C (0.18°F) at 30°C (86°F) / 100 mK

Frame rate: 50 Hz

Focal length: 7.5 mm  

Sensor type: uncooled microbolometer

Spectral range: 8 ... 14 µm

Measuring range object temperature: -20 ... 260°C / -4 ... 500°F

Measurement accuracy: ± 3°C / 5.4°F or 3% of the measured value, at 10 ... 35°C /  50 ... 95°F ambient temperature and > 0°C / 32°F object temperature

- General Technical Data:  

Display: Colour TFT, 6000 points with status display

Conversion: TRMS

Reference standards: IEC/EN61010-1, IEC/EN61326-1

Isolation: Double

Pollution degree: 2

Overload category: CAT IV 600 V, CAT III 1000 V

Battery type: 1 x 7.4V Li-Ion battery, 2300-mAh

Power supply charger: 100 / 240V AC, 50/60 Hz, 10V DC, 1 A

Battery level indicator: Yes

Automatic shutdown: After 15, 30 or 60 minutes of inactivity (deactivatable)

Fuses: F10A/1000V, 10 x 38 mm (Input 10 A); F800mA/1000V, 6 x 32 mm (Input mA, µA)

Test temperature: 18 ... 28°C / 64 ... 82°F

Operating conditions: 5 ... 40°C / 41 ... 104°F, <80% r.H.

Storage conditions: -20 ... 60°C / -4 ... 140°F, <80% r.H.

Maximum operating height: 2000 m / 2187 yd

Dimensions: 175 x 85 x 55 mm / 6.9 x 3.3 x 2.1 in

Weight: 540 g / 1 lb 3oz

- Technical Data DC Voltage:  

Measuring range; Resolution; Measurement accuracy; Input resistance; Overload protection

600 mV; 0.1 mV; ± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms

6V; 0.001V; ± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms

60V; 0.01V; ± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms

600V; 0.1V; ± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms

1000V; 1V; ± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms  

- Technical Data AC Voltage (TRMS):  

Measuring range; Resolution; Measurement accuracy (50 ... 60 Hz); Measurement accuracy (61 Hz ... 1 kHz); Overload protection

6V; 0.001V; ± (0.8% of measurement value +5 Dgt)±; (2.4% of measurement value +5 Dgt); 1000V DC / ACrms

60V; 0.01V; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms

600V; 0.1V; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms

1000V; 1V; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms  

- Technical Data DC and AC voltage (TRMS): 

Measuring range; Resolution; Measurement accuracy; Input resistance; Overload protection

6V; 0.001V; ± (2.4% of measurement value +20 Dgt); >10 MΩ; 1000V DC / ACrms

60V; 0.01V; ± (2.4% of measurement value +20 Dgt); >10 MΩ; 1000V DC / ACrms

600V; 0.1V; ± (2.4% of measurement value +20 Dgt); >10 MΩ; 1000V DC / ACrms

1000V; 1V; ± (2.4% of measurement value +20 Dgt); >10 MΩ; 1000V DC / ACrms  

- Technical Data Direct Current:  

Measuring range; resolution; Measurement accuracy; Overload protection  

600 µA; 0.1µA; ± (0.9% of measurement value +5 Dgt); Protection 800-mA / 1000 V  

6000 µA; 1 µA; ± (0.9% of measurement value +5 Dgt); Protection 800-mA / 1000V  

60-mA; 0.01-mA; ± (0.9% of measurement value +5 Dgt); Protection 800-mA / 1000V  

600-mA; 0.1-mA; ± (0.9% of measurement value +8 Dgt); Protection 800-mA / 1000V  

10 A; 0.01 A; ± (1.5% of measurement value +5 Dgt); Protection 10 A / 1000V  

- Technical Data Alternating Current (TRMS):  

Measuring range; Resolution; Measurement accuracy; Overload protection  

600 µA; 0.1 µA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V  

6000 µA; 1 µA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V  

60-mA; 0.01-mA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V  

600-mA; 0.1-mA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V  

10 A; 0.01 A; ± (1.5% of measurement value +5 Dgt); Protection 10 A / 1000V    

- Technical Data Coil Current:  

Measuring range; Resolution; Measurement accuracy (50 ... 60 Hz); Measurement accuracy (61 Hz ... 1 kHz); Overload protection

30 A; 0.01 A; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms

300 A; 0.1 A; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms

3000 A; 1 A; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms  

- Technical Data Diode Test:  

Test current: <1.5-mA  

Maximum voltage at the open circuit: 3.3V DC  

- Resistance and continuity test:  

Measuring range; Resolution; Measurement accuracy; Acoustic warning sound; Overload protection

600 Ω; 0.1Ω; ± (0.5% of measurement value +10 Dgt); >50 Ω; 1000V DC / ACrms

6 Ω; 0.001 kΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms

60 kΩ; 0.01 kΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms

600 kΩ; 0.1 kΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms

6 MΩ; 0.001 MΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms

60 MΩ; 0.01 MΩ; ± (2.5% of measurement value +10 Dgt); >50 Ω; 1000V DC / ACrms  

- Technical Data Frequency:  

Measuring range; Resolution; Measurement accuracy; Overload protection  

40 Hz ... 10 kHz; 0.01 Hz ... 0.001 kHz ± (0.5% of measurement value); 1000V DC / ACrms  

60 Hz; 0.01 Hz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms  

600 Hz; 0.1 Hz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms  

6 kHz; 0.001kHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms  

60 kHz; 0.01kHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms  

600 kHz; 0.1 kHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms  

6 MHz; 0.001 MHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms  

10 MHz; 0.01 MHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms    

- Technical Data Duty Cycle:  

Measuring range; Resolution; Measurement accuracy  

5 ... 95%; 0.1%; ± (1.2% of measurement value +2 Dgt)    

- Technical Data Capacitance:  

Measuring range; Resolution; Measurement accuracy; Overload protection  

60 nF; 0.01 nF; ± (1.5% of measurement value +20 Dgt); 1000V DC / ACrms  

600 nF; 0.1 nF; ± (1.2% of measurement value +8 Dgt); 1000V DC / ACrms  

6 µF; 0.001 µF; ± (1.5% of measurement value +8 Dgt); 1000V DC / ACrms  

60 µF; 0.01 µF; ± (1.2% of measurement value +8 Dgt); 1000V DC / ACrms  

600 µF; 0.1 µF; ± (1.5% of measurement value +8 Dgt); 1000V DC / ACrms  

6000 µF; 1 µF; ± (2.5% of measurement value +20 Dgt); 1000V DC / ACrms    

- Technical Data Temperature (Thermoelement Type K):  

Measuring range; Resolution; Measurement accuracy; Overload protection  

-40 ... 600°C / -40 ... 1112°F; 0.1°C / 0.18°F; ± (1.5% of measurement value 3°C / 5.4°F); 1000V DC / ACrms  

600 ... 1000°C / 1112°F ... 1832°F; 1°C / 1.8°F; ± (1.5% of measurement value 3°C / 5.4°F); 1000V DC / ACrms

Delivery scope:

1 x Digital multimeter PCE-HDM 20-ICA

2 x Measurement line

1 x Type K Type K thermocouple probe

2 x Li-ion battery

1 x Charger

1 x Power plug

3 x Attachment for power plug

1 x Micro-SD Card (8 GB)

1 x Magnet

1 x Fabric loop

1 x Temperature adapter

1 x User manual

1 x ISO calibration certificate 


Details

Datasheet


Manual
  • 품질 보증
  • 공인 보증
  • 집으로 배달
  • 간단하게 거래하기