For full functionality of this site it is necessary to enable JavaScript.

PCE HDM 20 디지털 멀티 미터

Specifications

Display: Colour TFT, 6000 points with status display

Conversion: TRMS

Reference standards: IEC/EN61010-1, IEC/EN61326-1

Isolation: Double

Pollution degree: 2

Overload category: CAT IV 600 V, CAT III 1000 V

Battery type: 1 x 7.4V Li-Ion battery, 2300-mAh

Power supply charger: 100 / 240V AC, 50/60 Hz, 10V DC, 1 A

Battery level indicator: Yes

Automatic shutdown: After 15, 30 or 60 minutes of inactivity (deactivatable)

Fuses: F10A/1000V, 10 x 38 mm (Input 10 A); F800mA/1000V, 6 x 32 mm (Input mA, µA)

Test temperature: 18 ... 28°C / 64 ... 82°F

Operating conditions: 5 ... 40°C / 41 ... 104°F, <80% r.H.

Storage conditions: -20 ... 60°C / -4 ... 140°F, <80% r.H.

Maximum operating height: 2000 m / 2187 yd

Dimensions: 175 x 85 x 55 mm / 6.9 x 3.3 x 2.1 in

Weight: 540 g / 1 lb 3oz 

Technical Data DC Voltage

Measuring range Resolution; Measurement accuracy; Input resistance; Overload protection

600 mV; 0.1 mV; ± (0.2% of measurement value + 5 Dgt);  >10 MΩ;  1000V DC / ACrms

6V; 0.001V;± (0.2% of measurement value + 5 Dgt); >10 MΩ;  1000V DC / ACrms

60V; 0.01V;  ± (0.2% of measurement value + 5 Dgt);  >10 MΩ; 1000V DC / ACrms

600V;  0.1V;  ± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms

 1000V; 1V; ± (0.2% of measurement value + 5 Dgt); >10 MΩ; 1000V DC / ACrms

Technical Data AC Voltage (TRMS)

Measuring range Resolution; Measurement accuracy

(50 ... 60 Hz); Measurement accuracy

(61 Hz ... 1 kHz); Overload protection

6V; 0.001V; ± (0.8% of measurement value +5 Dgt)±;

(2.4% of measurement value +5 Dgt); 1000V DC / ACrms

60V; 0.01V; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms

600V; 0.1V; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms

1000V; 1V; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms

Technical Data DC and AC voltage (TRMS)

Measuring range Resolution; Measurement accuracy; Input resistance; Overload protection

6V; 0.001V; ± (2.4% of measurement value +20 Dgt); >10 MΩ; 1000V DC / ACrms

60V; 0.01V; ± (2.4% of measurement value +20 Dgt); >10 MΩ; 1000V DC / ACrms

600V; 0.1V; ± (2.4% of measurement value +20 Dgt); >10 MΩ 1000V DC / ACrms

1000V; 1V; ± (2.4% of measurement value +20 Dgt); >10 MΩ ;1000V DC / ACrms

Technical Data Direct Current

Measuring range Resolution; Measurement accuracy; Overload protection

600 µA; 0.1µA; ± (0.9% of measurement value +5 Dgt); Protection 800-mA / 1000 V

6000 µA 1 µA; ± (0.9% of measurement value +5 Dgt); Protection 800-mA / 1000V

60-mA; 0.01-mA ± (0.9% of measurement value +5 Dgt); Protection 800-mA / 1000V

600-mA; 0.1-mA ± (0.9% of measurement value +8 Dgt); Protection 800-mA / 1000V

10 A; 0.01 A ± (1.5% of measurement value +5 Dgt); Protection 10 A / 1000V

Technical Data Alternating Current (TRMS)

Measuring range Resolution; Measurement accuracy; Overload protection

600 µA; 0.1 µA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V

6000 µA; 1 µA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V

60-mA; 0.01-mA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V

600-mA; 0.1-mA; ± (1.2% of measurement value +5 Dgt); Protection 800-mA / 1000V

10 A; 0.01 A; ± (1.5% of measurement value +5 Dgt); Protection 10 A / 1000V

Technical Data Coil Current

Measuring range Resolution; Measurement accuracy

(50 ... 60 Hz); Measurement accuracy (61 Hz ... 1 kHz); Overload protection

30 A; 0.01 A; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms

300 A; 0.1 A; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms

3000 A 1 A; ± (0.8% of measurement value +5 Dgt); ± (2.4% of measurement value +5 Dgt); 1000V DC / ACrms

Technical Data Diode Test

Test current: <1.5-mA

Maximum voltage at the open circuit: 3.3V DC

Resistance and continuity test

Measuring range Resolution; Measurement accuracy; Acoustic warning sound; Overload protection

600 Ω; 0.1Ω; ± (0.5% of measurement value +10 Dgt); >50 Ω; 1000V DC / ACrms

6 Ω; 0.001 kΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms

60 kΩ; 0.01 kΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms

600 kΩ; 0.1 kΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms

6 MΩ; 0.001 MΩ; ± (0.5% of measurement value +5 Dgt); >50 Ω; 1000V DC / ACrms

60 MΩ; 0.01 MΩ; ± (2.5% of measurement value +10 Dgt); >50 Ω; 1000V DC / ACrms

Technical Data Frequency

Measuring range; Resolution;

Measurement accuracy; Overload protection

40 Hz ... 10 kHz; 0.01 Hz ... 0.001 kHz; ± (0.5% of measurement value); 1000V DC / ACrms

60 Hz; 0.01 Hz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms

600 Hz; 0.1 Hz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms

6 kHz; 0.001kHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms

60 kHz; 0.01kHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms

600 kHz; 0.1 kHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms

6 MHz; 0.001 MHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms

10 MHz; 0.01 MHz; ± (0.09% of measurement value +5 Dgt); 1000V DC / ACrms

Technical Data Duty Cycle

Measuring range; Resolution; Measurement accuracy; Overload protection

60 nF; 0.01 nF; ± (1.5% of measurement value +20 Dgt); 1000V DC / ACrms 

600 nF; 0.1 nF; ± (1.2% of measurement value +8 Dgt); 1000V DC / ACrms

6 µF; 0.001 µF; ± (1.5% of measurement value +8 Dgt); 1000V DC / ACrms

60 µF; 0.01 µF; ± (1.2% of measurement value +8 Dgt); 1000V DC / ACrms

600 µF; 0.1 µF; ± (1.5% of measurement value +8 Dgt); 1000V DC / ACrms

6000 µF; 1 µF; ± (2.5% of measurement value +20 Dgt); 1000V DC / ACrms

Technical Data Temperature (Thermoelement Type K)

Measuring range; Resolution

Measurement accuracy; Overload protection

-40 ... 600°C / -40 ... 1112°F; 0.1°C / 0.18°F; ± (1.5% of measurement value 3°C / 5.4°F); 1000V DC / ACrms

600 ... 1000°C / 1112°F ... 1832°F; 1°C / 1.8°F ± (1.5% of measurement value 3°C / 5.4°F); 1000V DC / ACrms




Dilivery Contents 

1 x Multimeter PCE-HDM 20

2 x Measurement line

1 x Type K Type K thermocouple probe

2 x Li-ion battery

1 x Charger

1 x Power plug

3 x Attachment for power plug

1 x Micro-SD Card (8 GB) 

1 x Magnet

1 x Fabric loop

1 x Temperature adapter

1 x User manual 

Details

Manual


  • 품질 보증
  • 공인 보증
  • 집으로 배달
  • 간단하게 거래하기

할인과 정보를 받기 위해 등록하기