Powertek MC141 전압 - 전류 - 온도 - 저항용 휴대용 캘리브레이터
생산업체: POWERTEK Model: MC141 - 견적요구
- 연락처
Manufacturer: Powertek
Model: MC141
Voltage range from 0 to 750V DC/AC with uncertainty 0.01% | |
Current range from 0 to 2A DC/AC with uncertainty 0.02% | |
Calibrated sinusoidal output signal DC - 1kHz | |
Set standard resistors from 10Ohm to 100MOhm in decade values with uncertainty 0.02% | |
TC temperature sensor simulation R, S, B, J, T, E, K, N in range from -250oC to 1850oC | |
Cold junction point automatic compensation with internal Pt100 sensor | |
RS232 interface c/w with USB convertor (IEEE488 as option) | |
Easy operation, large display Weight 5kg | |
UKAS/NIST Traceable |
The MC141 Multifunction calibrator is designed for portable and bench use in process control environments, calibration laboratories, quality departments and production lines where electrical instrumentation requires testing and calibration. Calibration of voltmeters to 750V ac/dc, ammeters to 2A ac/dc, resistance ranges of multimeters and industrial transducer units can be performed easily. RS-232 interface enables its use in automated calibration and testing systems. The Model MC141 can work under Powertek SW applications like WinQbase and Caliber. |
MC141 Datasheet pdf | MC141 User Manual pdf
MC141 specifications
DC/AC voltage
range |
% of value
|
% of value
|
% of value
|
DC |
20Hz - 200Hz |
200Hz - 1000Hz |
|
0mV - 10mV * |
0.05 + 0.0 + 10µV |
0.20 + 0.05 + 20µV |
0.20 + 0.10 + 20µV |
10mV - 100mV |
0.01 + 0.001 + 10µV |
0.10 + 0.03 + 20µV |
0.15 + 0.05 + 20µV |
100mV - 1V |
0.008 + 0.002 |
0.05 + 0.005 |
0.07 + 0.01 |
1V - 10V |
0.008 + 0.002 |
0.05 + 0.005 |
0.07 + 0.03 |
10V - 100V |
0.015 + 0.004 |
0.05 + 0.01 |
0.07 + 0.03 |
100V - 750V |
0.018 + 0.004 |
0.03 + 0.02 |
0.10 + 0.03 |
* DC voltage from 0µV, AC voltage from 1mV |
DC/AC current |
range |
% of value
|
% of value
|
% of value
|
DC |
20Hz - 200Hz |
200Hz - 1000Hz |
|
1µA - 200µA |
0.05 + 0.0 + 20nA |
0.25 + 0.0 + 20nA |
0.30 + 0.10 + 20nA |
200µA - 2mA |
0.025 + 0.005 |
0.10 + 0.01 |
0.20 + 0.05 |
2mA - 20mA |
0.015 + 0.003 |
0.07 + 0.005 |
0.20 + 0.05 |
20mA - 200mA |
0.015 + 0.003 |
0.07 + 0.005 |
0.20 + 0.05 |
200mA - 2A |
0.015 + 0.005 |
0.1 + 0.005 |
0.25 + 0.05 |
When option 140-50 Current coil is used, add 0.3% uncertainty to the set current value specified in the above table. |
Frequency output |
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
TC temperature sensor simulation
|
Resistance
|
|||||||||||||||||||||||||||||
Accessories (included) |
Power line cable |
1 pc |
Operation manual |
1 pc |
Option 10/11 : Test cable for 1000V - 20 A, black/red |
2 pcs |
Options |
Option 140-50 |
Current coil with 25/50 turns.
|
|
Option 10 |
Test cable 20A/1000V (black) |
|
Option 11 |
Test cable 20A/1000V (red) |
|
Cable RS-232 |
RS-232, 2m |
|
Cable GPIB |
GPIB, 2m |
|
WinQbase |
Application SW for making database of meters and for automatic meter calibration. |
|
CALIBER |
SW module for automatic calibration of multimeters. |
Ordering information |
MC141 |
Basic version with RS-232 |
MC141 GPIB |
version with RS-232 and GPIB interface |
Voltage range from 0 to 750V DC/AC with uncertainty 0.01% | |
Current range from 0 to 2A DC/AC with uncertainty 0.02% | |
Calibrated sinusoidal output signal DC - 1kHz | |
Set standard resistors from 10Ohm to 100MOhm in decade values with uncertainty 0.02% | |
TC temperature sensor simulation R, S, B, J, T, E, K, N in range from -250oC to 1850oC | |
Cold junction point automatic compensation with internal Pt100 sensor | |
RS232 interface c/w with USB convertor (IEEE488 as option) | |
Easy operation, large display Weight 5kg | |
UKAS/NIST Traceable |
The MC141 Multifunction calibrator is designed for portable and bench use in process control environments, calibration laboratories, quality departments and production lines where electrical instrumentation requires testing and calibration. Calibration of voltmeters to 750V ac/dc, ammeters to 2A ac/dc, resistance ranges of multimeters and industrial transducer units can be performed easily. RS-232 interface enables its use in automated calibration and testing systems. The Model MC141 can work under Powertek SW applications like WinQbase and Caliber. |
MC141 specifications
DC/AC voltage
range |
% of value
|
% of value
|
% of value
|
DC |
20Hz - 200Hz |
200Hz - 1000Hz |
|
0mV - 10mV * |
0.05 + 0.0 + 10µV |
0.20 + 0.05 + 20µV |
0.20 + 0.10 + 20µV |
10mV - 100mV |
0.01 + 0.001 + 10µV |
0.10 + 0.03 + 20µV |
0.15 + 0.05 + 20µV |
100mV - 1V |
0.008 + 0.002 |
0.05 + 0.005 |
0.07 + 0.01 |
1V - 10V |
0.008 + 0.002 |
0.05 + 0.005 |
0.07 + 0.03 |
10V - 100V |
0.015 + 0.004 |
0.05 + 0.01 |
0.07 + 0.03 |
100V - 750V |
0.018 + 0.004 |
0.03 + 0.02 |
0.10 + 0.03 |
* DC voltage from 0µV, AC voltage from 1mV |
DC/AC current |
range |
% of value
|
% of value
|
% of value
|
DC |
20Hz - 200Hz |
200Hz - 1000Hz |
|
1µA - 200µA |
0.05 + 0.0 + 20nA |
0.25 + 0.0 + 20nA |
0.30 + 0.10 + 20nA |
200µA - 2mA |
0.025 + 0.005 |
0.10 + 0.01 |
0.20 + 0.05 |
2mA - 20mA |
0.015 + 0.003 |
0.07 + 0.005 |
0.20 + 0.05 |
20mA - 200mA |
0.015 + 0.003 |
0.07 + 0.005 |
0.20 + 0.05 |
200mA - 2A |
0.015 + 0.005 |
0.1 + 0.005 |
0.25 + 0.05 |
When option 140-50 Current coil is used, add 0.3% uncertainty to the set current value specified in the above table. |
Frequency output |
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
TC temperature sensor simulation
|
Resistance
|
|||||||||||||||||||||||||||||
Accessories (included) |
Power line cable |
1 pc |
Operation manual |
- 품질 보증
- 공인 보증
- 집으로 배달
- 간단하게 거래하기