For full functionality of this site it is necessary to enable JavaScript.

TOB TOB-CT-4008-5V10mA-1 배터리 테스터 3 범위 (0-10mAh, 0-5V)

Voltage: AC 220V ±10%, 50Hz

Resolution: AD: 16bit  DA: 16bit

Input Resistance: ≥1 GΩ

Input Power: 25W

Voltage

Constant Voltage Range: 25mV-5V

Discharge Min Voltage: -5V

Accuracy: ± 0.05% of FS

Stability: ± 0.05% of FS

Current

Per Channel Current Range: Range 1: 5uA-1mA, Range 2: 1mA-5mA, Range 3: 5mA-10mA

Accuracy: ± 0.05% of FS

Constant voltage cutoff current: Range 1: 2uA, Range 2: 0.01mA, Range: 0.02mA

Stability: ± 0.05% of FS

Power

Per Channel Output Power: 0.05W

Stability: ± 0.1% of FS

Time

Current Response Time: <500us (10%FS-90%FS)

Step Time Range: ≤(365*24 )hour/step, Time Form Support 00 : 00 : 00 : 00 (h min s ms)

Data Recording

Record Condition

Minimum Time Interval: 100ms

Minimum Voltage Interval: 10mV

Minimum Current Interval

Range 1: 2uA, Range 2: 0.01mA, Range 3: 0.02mA

Record Frequency: 10Hz

Charge

Charge Mode: Constant Current Charge, Constant Voltage Charge, Constant Current and Constant Voltage Charge, CPC

End Conditon: Voltage, current, relative time, capacity, -△V

Discharge

Discharge Mode: CCD, CPD, CRD, CVD, Constant Current and Constant Voltage Discharge

End Condition: Voltage, Current, Relative Time, Capacity, -△V

Pulse

Charge: CCC, CPC

Discharge: CCD, CPC

Min Pulse Width: 500ms

Pulse number: A single pulse step supports 32 different pulses

Automated Switch: Automated swith from charge to discharge for each pulse

End Condition: Voltage, Test Time

Cycle

Loop Measure Range: 1~65535 times

Max Steps Per Loop: 254

Nested Loop: Nested loop Function, Max Support 3 Layers

Protection

Software Protection

Power-down Data Protection

Off-line Testing Function

Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time

Hardware Protection: Additional Anti-reverse Protection Model

Channel Features: Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure

Channel Control Mode: Independent Control

DCIR testing: Support

Voltage and Current Testing Sample: 4-wire connecting

Noise: <45dB

Database: MySQL Database

A Means of Communication of Upper Machine: TCP/IP Protocol

Data Output: EXCEL、TXT、Graph

Communication Interface: Ethernet Port

Per Unit Main Channels No.: 8

Dimensions:  483 * 310 * 48 (mm)

Details

Datasheet

  • 품질 보증
  • 공인 보증
  • 집으로 배달
  • 간단하게 거래하기