For full functionality of this site it is necessary to enable JavaScript.

YOKOGAWA CL250 Clamp meter (AC/DC 2000A; mean value)

DC current: 400/2000A; 1.5+2

AC current: 400A/2000A(0~1000A), 2000A(1001~2000A); 1.5+2 (50/60Hz) at 400A/2000A(0~1000A)

DC voltage: 400/1000V; 1.0+2 

AC voltage: 400/750V; 1.5+2 (50/60Hz)

Resistance: 400/4000Ω; 1.5+2, Beeps at below 50 35Ω(continuity check)

DC output: DC400A(0~400mV), DC2000A(0~200mV), AC400A(0~400mV), AC2000A(0~100mV/0~1000A), AC2000A(100.1~200mV/1001~2000A)

Method of detection: Mean value

Display: LCD(Digital display:3999 counts)

Response time: Approx. 2 seconds

Range switching: Manual-range(on current, voltage range) /Auto-range(on resistance range)

Peak hold: On all range

Max hold: On current/voltage range

Operating temperat ure and humidity : 0-40C 85% RH or less (no condensation)

Effect of external magnetic field: 4A or less at 400A/m

Effect of conductor position:   (1.5% rdg + 3dgt) or less

Safety standard: Conforms EN61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage: 1000Vrms or less

Withstanding voltage: 8200V AC for 5 sec

Power supply: R6P(SUM-3)x2 or LR6x2

Batttery life: Approx. 100 hours (continuous)

Consumed current: Approx. 9mA

Sleep function: Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor: 55mm  at  maximum

Dimensions: Approx. 105(W) 250(H) 49(D)mm

Weight: Approx. 530g

Accessories: User's manual, Test Lead(98072), Output plug(98012), batteries, carrying case(93034)

Details