Output capacity: 5KVA
Output Current (220V): 22.8A
Input power: Single phase 200V±15%
Output phase: Single Phase
Output voltage: Auto:(Low gear)1~150.0V,(High gear)150.1~300.0V Hold:(high gear)1~300V
Output frequency: 45~65Hz continuous,adjustable
Frequency stability: 0.1%
Voltage stability: ≤1%
Transient recover time: 20ms
Over current protection: 1.05 rate, 1.1 rated
Protection mode: Short-circuit,overload and power device overheat protection
Display: VFD
Communication: Standard:RS232,Optional:RS485,Remote Control
Dimension: 483*750*400
Weight: 80 kg
Product Detail
Main features
High-frequency pulse-width modulation and IGBT driver,stable sine wave to simulate various state grid conditions,clean power;
Patented impact technlolgy for impact loads,such as resistive,capaciteive,inductive and mixed loads;
High-end clear VFD/LED high-density laminated structure,small size,light;
TS Series with over-voltage protection for internal circuits;
Online adjustable voltage/frequency to support remote PC communication control;
Over-current,over-power,overheating and abnormities protection,sound/light alarm;
Provide 6 shortcut groups to save voltage,frequency and upper/lower voltage deviation settings;
20KW and models provide cable drop compensation function to clear cable voltage drop;
Optional analog control interfaces for voltage/frequency output.
Order information and extended functions
AN97H Series:300V/45-65HZ,capacity 500VA 1kVA,2kvA,3kVA,5kVA,10kVA.
AN97TS series:300V/45-65Hz,capacity 15kVA,20kVA,30kVA,45kVA,60kVA,100kVA.
Output voltage can be up to 400V,600V,need to modify.
|
Type
|
AN97H series
|
AN97TS series
|
|
Input power
|
Single phase 200V±15%
|
3-phase 4-wires/3×220V±15%
|
|
Output phase
|
Single Phase
|
|
Output voltage
|
Auto:(Low gear)1~150.0V,(High gear)150.1~300.0V Hold:(high gear)1~300V
|
|
Output frequency
|
45~65Hz continuous,adjustable
|
|
Distortion
|
2%
|
|
Frequency stability
|
0.1%
|
|
Power effect
|
1%
|
|
Voltage stability
|
≤1%
|
|
Load effect
|
1%
|
|
Transient recover time
|
20ms
|
|
Over current protection
|
1.05 rate<="" span="">
1.1 rated<="" span="">
|
|
Protection mode
|
Short-circuit,overload and power device overheat protection
|
|
Loading capacity
|
Can Start a inductive load which capacity is less than 0.5 rated power
Capacity of AC power supply,or rectifier load which crest factor is less than 3.0
|
|
Memory function
|
Save the settings before turn off
|
|
Shortcut group
|
6 groups
|
|
Preset function
|
Output voltage,output frequency and output voltage tolerance can be preset under standby status
|
|
Adjustment online
|
Under running status,output voltage can be adjustable through “+”or”-“button
|
|
Voltage
|
Resolution:0.1V Accuracy: ±(0.8%×reading +0.2%×range)
|
|
Current
|
Resolution:0.001A/0.01A
Accuracy: ±(2%×reading+1%×rated output)
|
Resolution: 0.01A
Accuracy: ±(2%×reading+1%×rated output)
|
|
Power
|
Resolution:0.001KW/0.01KV
Accuracy: ±5%
|
Resolution: 0.01KV
Accuracy: ±5%
|
|
Display
|
VFD
|
LED 4-windows
|
|
Communication
|
Standard:RS232,Optional:RS485,Remote Control
|
| |
|
|
|
|
Model
|
AN97000H(F)
|
AN97001H(F)
|
AN97002H(F)
|
AN97003H(F)
|
AN97005H
|
AN97010H(F)
|
AN97010TSH(F)
|
|
Output capacity
|
500VA
|
1kVA
|
2kVA
|
3kVA
|
5KVA
|
10 kVA
|
10 kVA
|
|
Output Current
|
110V
|
4.6A
|
9.2A
|
18.2A
|
27.4A
|
45.6A
|
91A
|
91A
|
|
220V
|
2.3A
|
4.6A
|
9.1A
|
13.7A
|
22.8A
|
45.5A
|
45.5A
|
|
Efficiency
|
≥70%
|
≥80%
|
|
Dimension W×H×D(mm)
|
483*200*380
|
483*550*400
|
483*750*400
|
483*902*600
|
|
Weight(kg)
|
20kg
|
54kg
|
62kg
|
80
|
195
|
| |
|
|
|
|
|
|
|
|
|
|
|
Model
|
AN97015TS(F)
|
AN97020TS(F)
|
AN97030TS(F) </
|