For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Codel GCEM 50E ເຄື່ອງວິເຄາະການປ່ອຍອາຍພິດ (CO2, H2O, O2, CO, NO, NO2, N2O, SO2, HCl, CH4)

ຕິດຕໍ່
ການຊຳລະເງິນທີ່ປອດໄພ
ການຮັບປະກັນຄຸນນະພາບ
ປ່ຽນ ແລະ ສົ່ງຄືນງ່າຍ
ມີບໍລິການຈັດສົ່ງ

Alternative Measurement Units: mg/Nm³; mg/m³; Vol.%

Accuracy: <2% of range

Flue Gas Temperature: 0 – 1200°C

Ambient Temperature: -20°C to 50°C

Zero Drift: Automated daily zero calibration

Span Drift: Manual span calibration on demand

Response Time (T90): < 180 seconds

Outputs: 1 x RS485 (standard); 16 x analog outputs (optional); 16 x relay outputs (optional)

Inputs: 1 x 4–20 mA input; 3 x digital inputs

Software: Local touch screen HMI; CODEL Cloud compatible

Power Supply: 240 VAC (-15% to +10% from nominal supply)

Power Consumption:

Cabinet: 15 kW

Sample line: 80 W per meter (typical, supplier dependent)

Sample probe: 800 W (typical, supplier dependent)

Air Supply: Oil-free instrument air; 1 L/min (standard operation); 10 L/min (calibration); @ 5.5 Bar (minimum)

Repeatability: <2% of range

Heated Sample Line (Dual Core): Sample and span gas lines with self-regulating heating up to 180°C; mains supply for sample probe

Standard Probe & Sample Line: Sample probe and sample line temperatures should be selected based on specific application conditions

Stack Gas Temperature: 0 – 300°C / 0 – 600°C / 0 – 900°C (options available)