Voltage DC Range: 0 to ±1020V/±0.01% of setting
Current DC Range: 0 to ±20.5A/ ±0.05% of setting
Resistance Range: 0 to 190 MO, 19 values in x1 and x1.9 : ±0.025% of setting
Voltage AC Range: 1 mV to 1020V (45Hz to 1 kHz, Sine)/: ±0.1% of setting
Current AC Range:29 mA to 20.5A (45 Hz to 1 kHz, Sine)/ ±0.1% of setting
DC Power Range:10.9 mW to 20.5 kW/ ±0.11% of setting
AC Power Range: 10.9 mW to 20.5 kW (45-65 Hz, PF=)/ ±0.36% of setting
Phase Range: 0 to ± 179.99° (45 Hz to 1 kHz) / ±0.25° of setting
Frequency Range: 45 Hz to 1 kHz / ±50 ppm of setting
Standard Interfaces: RS-232 and Ethernet
Line Power: Line Voltage (selectable): 100V, 120V, 220V, 240V (47 to 63 Hz)
Power Consumption: 600 VA
Dimensions: 19.3 cm x 43.2 cm x 53.8 cm
Weight: 22 kg
Datasheet
Option
5080A/MEG: Multi-Product calibrator with Megohm Meter Calibration Option
5080A/SC: Multi-Product Calibrator with Oscilloscope Calibration Option
5080A/SC/MEG: Multi-Product Calibrator with Megohm Meter and Oscilloscope Calibration Option
5080/CAL: calibration software
9100-200: 10/50 Turn Current Coil
5500A/COIL: 50-Turn Current Coil
5080A: Megohm Meter Calibration Option
5080A Megohm Meter Calibration Option
5080A/CASE: 5080A/CASE
|
Technical Specifications
|
|
Voltage DC
|
|
|
Range: 0 to ±1020V
|
|
|
Best 1 Year Specification: ±0.01% of setting
|
|
|
Current DC
|
|
|
Range: 0 to ±20.5A
|
|
|
Best 1 Year Specification: ±0.05% of setting
|
|
|
Resistance
|
|
|
Range: 0 to 190 MO, 19 values in x1 and x1.9
|
|
|
Best 1 Year Specification: ±0.025% of setting
|
|
|
Voltage AC
|
|
|
Range: 1 mV to 1020V 45Hz to 1 kHz, Sine
|
|
|
Best 1 Year Specification: ±0.1% of setting
|
|
|
Current AC
|
|
|
Range:29 mA to 20.5A 45 Hz to 1 kHz, Sine
|
|
|
Best 1 Year Specification: ±0.1% of setting
|
|
|
DC Power
|
|
|
Range:10.9 mW to 20.5 kW
|
|
|
Best 1 Year Specification: ±0.11% of setting
|
|
|
AC Power
|
|
|
Range: 10.9 mW to 20.5 kW 45-65 Hz, PF=1
|
|
|
Best 1 Year Specification: ±0.36% of setting
|
|
|
Phase
|
|
|
Range: 0 to ± 179.99° 45 Hz to 1 kHz
|
|
|
Best 1 Year Specification: ±0.25° of setting
|
|
|
Frequency
|
|
|
Range: 45 Hz to 1 kHz
|
|
|
Best 1 Year Specification: ±50 ppm of setting
|
|
|
General Specifications
|
|
Warm up Time
|
|
|
Twice the time since last warmed up, to a maximum of 30 minutes
|
|
|
Settling Time
|
|
|
Less than 5 seconds for all functions and ranges except as noted
|
|
|
Standard Interfaces
|
|
|
Temperature Performance
|
|
Operating: 0°C to 50°C
|
|
Calibration (tcal):15°C to 35°C
|
|
Storage:-20°C to +70°C
|
|
|
Temperature Coefficient
|
|
|
Temperature coefficient for temperatures outside tcal ±5 °C is 10 % of the stated specification per °C for temperatures in the range of 0 °C to 35 °C. Above 35 °C, the temperature coefficient is 20 % of the stated specification per °C.
|
|
|
Relative Humidity
|
|
Operating: <80% to 30°C, <70% to 40°C, <40% to 50°C
|
|
Storage:<95%, non-condensing
|
|
|
Altitude
|
|
Operating: 2,000m (6,500 ft) maximum
|
|
Non-operating: 12,200m (40,000 ft) maximum
|
|
|
Safety
|
|
Meets EN. 61010-1:2001, CAN/CSA-C22.2 No. 61010-1-04, UL 61010-1: 2004
|
|
|
Analog Low Isolation
|
|
|
EMC
|
|
|
Line Power
|
|
Line Voltage (selectable): 100V, 120V, 220V, 240V
|
|
Line Frequency: 47 to 63 Hz
|
|
Line Voltage Variation: + 10% about line voltage setting
|
|
|
Power Consumption
|
|
|
Calibration Documentation
|
Report of calibration with data included; 17025 accredited report optional
|
|
Dimensions
|
|
Height:19.3 cm (7.6 in)
|
|
Width:43.2 cm (17 in), 44.3 cm (17.5 in) including handles
|
|
Depth:53.8 cm (21.2 in)
|
|
|
Weight (without options)
|
|
|
Absolute Uncertainty Definition
|
|
The specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. It is not necessary to add anything to determine the total specification for the temperature range indicated.
|
|
|
Specification Confidence Interval
|
|