Technical Data
Inputs
Number:4 voltage and current (3 phases + neutral)
Maximum voltage:1000 Vrms (6 kV peak)
Maximum sampling speed:200 kS/s on each channel simultaneously
Volt/Amps/Hertz
Vrms (AC + DC) Measurement range:1 … 1000 V
Accuracy:0.1% of Vnom
Vpeak Measurement range:1 … 1400 V
Accuracy:5% of Vnom
Crest factor, voltage Measurement range:1.0 … > 2.8
Accuracy:±5%
Arms (AC + DC) Measurement range:0 … 20 kA
Accuracy:±0.5% ± 5 counts
Apeak Measurement range:0 … 5.5 kA
Accuracy:5%
Crest factor, A Measurement range:1 … 10
Accuracy:±5%
Hz 50 Hz nominal Measurement range:40 … 70 Hz
Accuracy:±0.01 Hz
Dips and swells
Vrms (AC+DC)2Measurement range:0.0% … 100% of Vnom
Accuracy:±0.2% of nominal voltage
Arms (AC+DC) ? Measurement range:0 …. 20 kA
Accuracy:±1% … ± counts
Harmonics
Harmonic (interharmonic) (n) Measurement range:DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7
Vrms Measurement range:0.0 … 1000 V
Accuracy:±0.05% of nominal voltage
Arms Measurement range:0.0 ± 4000 mV x clamp scaling
Accuracy:±5% ± 5 counts
Watts Measurement range:Depends on clamp scaling and voltage
Accuracy:±5% ± n x 2% or reading, ± 10 counts
DC voltage Measurement range:0.0 ± 1000 V
Accuracy:±0.2% of nominal voltage
THD Measurement range:0.0 … 100.0%
Accuracy:±2.5% V and A (± 5% Watt)
Hz Measurement range:0 … 3500 Hz
Accuracy:± 1 Hz
Phase angle Measurement range:-360° … +360°
Accuracy:± n x 1.5°
Power and energy
Watt, VA, VAR Measurement range:1.0 … 20.00 MVA1
Accuracy:±1% ± counts
kWh, kVAh, kVARh Measurement range:00.00 … 200.0 GVAh1
Accuracy:± 1.5% ± 10 counts
Power Factor/ Cos ⊕ / DPF Measurement range:0 … 1
Accuracy:± 0.03
Flicker
Pst (1 min), Pst, Plt, PF5 Measurement range:0.00 … 20.00
Accuracy:±5%
Unbalance
Volts Measurement range:0.0 … 5.0%
Accuracy:±0.5%
Current Measurement range:0.0 … 20%
Accuracy:± 1%
Transient Capture
Volts Measurement range:±6000 V
Accuracy:±2.5% of Vrms
Minimum detect duration5 µs (200kS/s sampling)
Inrush mode
Arms (AC+DC) Measurement range:0.000 … 20.00 kA1
Accuracy:±1% of meas ± 5 counts
Inrush duration (selectable) Measurement range:7.5 s … 30 min
Accuracy:±20 ms (Fnom = 50 Hz)
Autotrend recording
Sampling:5 readings/sec continuous sampling per channel
Memory:1800 min, max and avg points for each reading
Recording time:Up to 450 days
Zoom:Up to 12x horizontal zoom
Memory
Screens & data:50, shared memory divided between logging, screens and data sets
Notes1Depending on clamp scaling
2Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle
The advanced functions Interharmonics, Energy, Transients and Inrush are optional for the Fluke 434 and standard available on the Fluke 435.
Environmental Specifications
Operating Temperature:0 °C to +50 °C
Safety Specifications
SafetyEN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV ANSI/ISA S82.01
Mechanical & General Specifications
Size256 x 169 x 64 mm
Weight1.1 kg
Battery Life
Rechargeable NiMH pack (installed):>7 hours
Battery charging time:4 hours typical
Shock & Vibration
Shock:30 g
Vibration:3 g according to MIL-PRF-28800F Class 2
CaseRugged, shock proof with integrated protective holster, IP51 (drip and dust proof)
Warranty3 years