Measuring principle:
Electrochemical (EC): for toxic gases and oxygen
Catalytic combustion (CC): for flammable gases and vapors (up to 100%LEL)
Infrared (IR): for flammable gases and vapors and carbon dioxide
Measuring ranges: sensor dependent
Response time: sensor dependent
Expected average life of the sensor: sensor dependent
Measuring gas supply: via diffusion mode
Display: illuminated LCD full graphics display, automatic size setting for optimum reading, displays the battery capacity, gas concentration as current value and peak value
Alerting: depending on the gas type 3 or 2 momentary value and 2 exposure level alarms, battery alarm with visual and acoustical signaling as well as display on the screen, color of the display depending on the alarm state (orange/red).
Horn: 103 dB(A) (can be reduced to 90 dB(A))
Zero point and sensitivity adjustment: manual or automatic with an adjustment program, if necessary, test gas supply via the “SMART CAP” with 0.5...0.6slpm
Radio: optional 868MHz for EU; range approx. 700 m (free field)
optional 915MHz for USA; range approx. 300 m (free field)
Power supply: NiMH battery module; 2.6V 2100mAh; rechargeable
Operating time:
without Radio:
approx. 13h (EC+CCPS+IR); approx. 9h (EC+CC+IR)
approx. 21h (EC+CCPS); approx. 13h (EC+CC)
with Radio:
approx. 65h (EC); approx. 23h (EC+IR)
approx. 10h (EC+CCPS+IR); approx. 7,5h (EC+CC+IR)
approx. 14h (EC+CCPS); approx. 10h (EC+CC)
approx. 26h (EC); approx. 15h (EC+IR)
Climatic conditions
for operation: -20...+50°C | 5...95%r.h. | 70...130kPa
for storage: -25...+55°C | 5...95%r.h. | 70...130kPa (recommended 0...+30°C)
Housing:
Material: rubberized polycarbonate
Dimensions: 68 x 100 x 39 mm (W x H x D)
Weight: up to 275 g (depending on sensor configuration)
Protection class: IP67