Introducing the DAS1800 high data rate recorder

26/09/y 14:28:00

The DAS1800 is manufactured by B&K Precision, and is a completely new design compared to its predecessors. So let's go into the details in the article below to see what improvements this model has!

Overview of DAS1800

With more input module slots, the performance of the DAS1800 is significantly improved, the weight is lighter, and the storage capacity is also increased for long-term high-speed measurement data recording. 

Not to mention, the redesigned user interface is quite easy to use and fully integrated with time-saving features. The functionality of the DAS1800 can also be expanded with factory options such as an integrated Li-Ion battery that provides up to 3.5 hours of operation and protection against power failure.

Improvements in both design and features compared to previous versions

Diverse slots

Matching the number of channels and measurement types in a test plan to the manufacturer's product can sometimes be difficult, resulting in wasted costs on unused channels. 

However, with 10 input module slots and 4 or 8 channel module options, the DAS1800 offers options that help users easily customize the number of channels for each type of measurement. Users can also take advantage of empty slots and quickly reconfigure modules as testing needs change, ensuring time savings and optimized performance.

Available input modules:

- D18-UNI4:

4-channel isolated universal input module for measuring voltage up to 600 VDC or 424 VRMS, temperature with thermocouples or current (with shunt) at up to 1 MSa/sec/channel

- D18-HIZ4:

High impedance version of the UNI4 module with 10 MΩ for range ≥ ±1 V and 25 MΩ for range ≤ ±0.5mV

- D18-MUX8:

8-channel non-isolated differential input module for measuring voltage up to ±48V, temperature by thermocouple and RTD, current 4-20 mA (with shunt) and resistance up to 10kΩ

Maximize data recording and storage

Running out of storage space can disrupt long-term tests, and having to delete or transfer files is not the right choice. The S1800 now comes with a standard 2TB SSD, so users can record hours of data at the full 1 MSa/s sampling rate.

Intuitive interface, easy to use

With a 15.6-inch Full HD multi-touch display and a redesigned user interface, the DAS1800 makes it easier for you to analyze recorded data. Tabs along the top of the interface are arranged to support common workflows, and the touchscreen makes it easy to navigate with just a finger. The DAS1800 also offers time-saving tools like one-finger scrolling, pinch-to-zoom, one-click automatic measurement, and cursors for analyzing recorded data.

Easy to carry anywhere:

Weight is quite a problem when you want to carry testing equipment to remote locations. As for the DAS1800, with the built-in Li-Ion battery option weighing just 15 pounds and the 3-module system weighing less than 20 pounds, you can easily move it around without feeling bulky or heavy.
Conclude:

Above is some basic information about the DAS1800 high-speed data recorder. For more details, please contact us.

Refer to the product at: DAS1800 high-speed data recorder

ຂ່າວທີ່ກ່ຽວຂ້ອງ

DC, Pulsed DC, or RF: Selecting a Plasma Source Based on Material and Process
23/11/y 16:55:48

In sputtering, positive ions (typically Argon) are accelerated toward a target to bombard and dislodge material. A stable ion current can only be maintained if electric charge does not accumulate on the target surface. The simulation below illustrates this principle qualitatively: the blue trace follows the waveform, while the amber-colored bar represents the level of charge accumulated on the target surface

Errors in Measuring Rebar Diameter within Concrete
23/11/y 13:50:41

In the quality assessment of reinforced concrete structures using non-destructive testing (NDT) methods, determining the diameter (d) of reinforcing bars directly on a completed structural element often results in significantly greater margins of error compared to measuring the thickness of the concrete cover. If the identified diameter deviates by one or two standard size increments (for example, if a D16 bar is misidentified as a D20 or D12), the entire analysis—including the calculation of load-bearing capacity and the verification of the structural design—loses its reliability.

Assessment and Retrofitting of Reinforced Concrete Structures After Fire Exposure in Accordance with TCVN 14104:2025
23/11/y 11:48:42

In accordance with the principles for the preservation and post-fire structural assessment stipulated in TCVN 14104:2025, the inspection entity must accurately quantify the extent of cross-sectional degradation in heat-exposed concrete, the presence of subsurface delamination, and the condition of the internal steel reinforcement before developing a strengthening plan.

Hướng dẫn đo nghiệm thu chiều dày lớp bê tông bảo vệ đúng chuẩn TCVN 9356:2012 & Luật Xây dựng 2025
21/11/y 10:00:27

Để kết quả đo đạt độ tin cậy pháp lý khi làm hồ sơ hoàn công và nghiệm thu với tư vấn giám sát, kỹ sư hiện trường và thí nghiệm viên phòng LAS-XD cần làm chủ quy trình vận hành máy đo chiều dày lớp bê tông bảo vệ, kiểm soát các yếu tố gây nhiễu từ trường và xử lý số liệu đúng quy chuẩn.

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ

ເຂົ້າເຖິງຜູ້ຊ່ຽວຊານທີ່ໄດ້ຮັບການຢັ້ງຢືນຂອງພວກເຮົາໂດຍກົງ