Accessories: Test lead GTL-104A x 2,GTL-105A x 1 ; European test lead GTL-203A x 1,GTL-204A x 2, GTL-201A x1, User manual x 1, Power cord x 1
|
|
GPS-3303
|
| DC OUTPUT |
| |
CH1
|
CH2
|
CH3
|
|
| Voltage |
0~30V
|
5V Fixed
|
| Current |
0~3A
|
3A Max.
|
| Tracking Series Voltage |
0~60V
|
| Tracking Parallel Current |
0~6A
|
|
|
CONSTANT VOLTAGE OPERATION (CH1, CH2)
|
| Line Regulation |
≦0.01% + 3mV |
| Load Regulation |
≦0.01% + 3mV (rating current≦3A) ≦0.02% + 5mV (rating current >3A) |
| Ripple & Noise |
≦1mVrms 5Hz ~ 1MHz |
| Recovery Time |
≦100μS ( 50% Load change, Minimum load 0.5A ) |
|
CONSTANT CURRENT OPERATION (CH1, CH2)
|
| Line Regulation |
≦0.2% + 3mA |
| Load Regulation |
≦0.2% + 3mA |
| Ripple Current |
≦3mArms |
|
TRACKING OPERATION (CH1, CH2)
|
| Tracking Error |
≦0.5% + 10mV of CH1 |
| Series Regulation |
≦0.01% + 5mV |
| Load Regulation |
≦300mV |
| Ripple & Noise |
≦2mVrms, 5Hz ~ 1MHz |
|
CH3 OPERATION
|
| CH3 Voltage |
2.2V ~ 5.2V |
| Line Regulation |
≦5mV |
| Load Regulation |
≦15mV |
| Ripple & Noise |
≦2mVrms 5Hz ~ 1MHz |
| Current Output |
1A |
|
METER
|
Digital Accuracy |
3 Digits 0.5" LED Display GPS-4303/3303 Out ON Accuracy ± (0.5% of rdg + 2 digits) GPS-4303/3303 Out OFF Accuracy ± (0.5% of rdg + 8 digits) GPS-2303 Accuracy ± (0.5% of rdg + 2 digits)
|
|
INSULATION
|
| Chassis and Terminal |
≧DC 500V / 20MΩ |
| Chassis and AC Cord |
≧DC 500V / 30MΩ |
| POWER SOURCE |
| |
AC 100V/120V/220V ±10%, 230V(+10% ~ -6%), 50/60Hz |
| DIMENSIONS & WEIGHT |
| |
255(W) x 145(H) x 265(D)mm, Approx. 7kg |