For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

HUATEC TG8830F Coating Thickness Gauge

ModelTG-8830F
ຕົ້ນກຳເນີດChina
ບໍ່ລວມ VAT
9,918,750 VND
ລວມ VAT
10,712,250 VND
ການຊຳລະເງິນທີ່ປອດໄພ
ການຮັບປະກັນຄຸນນະພາບ
ປ່ຽນ ແລະ ສົ່ງຄືນງ່າຍ
ມີບໍລິການຈັດສົ່ງ

Technical Specification

Measuring range

F1:0~1250μm,

Measuring accuracy

1 point calibration : ±(2%+1)2 point calibration : ±(1%+1)

Calibration

1 point calibration /2 point calibration /basic calibration

Display resolution

0.1um (0~99.9um) / 1um (Over 100um)

Weight

250g(including battery package )

Operation environment

Temperature: 0℃~50℃ humidity: 20%RH~90%RH

Operation mode

Direct testing mode and block statistics mode

Measuring mode

continuous/single

Shutdown mode

manual/automatic

Operation alarm

Ring music to alarm mistake

Signal Dealing

Threshold

Limits setting and automatically alarm measured values out of limit

Data analysis

Analyzing a batch of measuring values via histogram

Statistic function

Mean/ Standard deviation / Number of measurements/ Maximum/ Minimum

Data Merory

Thickness values

500 measuring data

Delete

Single doubtful data / All data of one group

Power supply

Battery

9V Nickel-hydride/ alkaline batteries

Power battery inspection

low voltage indication

Standard delivery

Main unit

1

Integrated probe (F1)

1

Calibration foil set

4

Calibration base set

1

9V alkaline battery

1

Instruction manual

1

Technical Specification

Measuring range

F1:0~1250μm,

Measuring accuracy

1 point calibration : ±(2%+1)2 point calibration : ±(1%+1)

Calibration

1 point calibration /2 point calibration /basic calibration

Display resolution

0.1um (0~99.9um) / 1um (Over 100um)

Weight

250g(including battery package )

Operation environment

Temperature: 0℃~50℃ humidity: 20%RH~90%RH

Operation mode

Direct testing mode and block statistics mode

Measuring mode

continuous/single

Shutdown mode

manual/automatic

Operation alarm

Ring music to alarm mistake

Signal Dealing

Threshold

Limits setting and automatically alarm measured values out of limit

Data analysis

Analyzing a batch of measuring values via histogram

Statistic function

Mean/ Standard deviation / Number of measurements/ Maximum/ Minimum

Data Merory

Thickness values

500 measuring data

Delete

Single doubtful data / All data of one group

Power supply

Battery

9V Nickel-hydride/ alkaline batteries

Power battery inspection

low voltage indication

Standard delivery

Main unit                

1  

Integrated probe (F1)

1

Calibration foil set

4

Calibration base set

1

9V alkaline battery

1

Instruction manual

1

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ

ເຂົ້າເຖິງຜູ້ຊ່ຽວຊານທີ່ໄດ້ຮັບການຢັ້ງຢືນຂອງພວກເຮົາໂດຍກົງ