For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

INSIZE 5401-TC11 ເຄື່ອງວັດແທກຄວາມຫນາຂອງເຄືອບ (0-1500μm)

ບໍ່ລວມ VAT
13,460,140 VND
ລວມ VAT
14,536,951 VND
ການຊຳລະເງິນທີ່ປອດໄພ
ການຮັບປະກັນຄຸນນະພາບ
ປ່ຽນ ແລະ ສົ່ງຄືນງ່າຍ
ມີບໍລິການຈັດສົ່ງ

Probe: FM (included) magnetic induction probe

Range: 0-1500μm

Resolution: 0.1μm (<100μm)

Accuracy*:

Zero calibration: ±(1μm+2%L)

One-point calibration: ±(1μm+2%L)

Two-point calibration: ±(1μm+(1-2)%L)

Multi-point calibration: ±(1μm+1%L)

Measuring mode: single point measurement, scan mode, differential mode, average mode

Calibration mode: zero calibration, one-point calibration, two-point calibration, multi-point calibration

Test frequency: 3 times per second

Minimum substrate thickness: 0.5mm

Minimum measuring area: Ø7mm

Minimum curvature radius of convex workpiece: 1.5mm

Data storage: 500 groups

Interface: USB

Operation temperature: -10°C~50°C

Power supply: 3x1.5V pin AAA

Dimension: 150×70×30mm

Weight: 160g

Probe: NM (optional) eddy current probe

Range: 0-1500μm (chrome plating on copper: 0-40μm)

Resolution: 1μm (100μm~1500μm)

Accuracy*:

Zero calibration: ±(1μm+2%L)

One-point calibration: ±(1μm+2%L)

Two-point calibration: ±(1μm+(1-2)%L)

Multi-point calibration: ±(1μm+1%L)

Measuring mode: single point measurement, scan mode, differential mode, average mode

Calibration mode: zero calibration, one-point calibration, two-point calibration, multi-point calibration

Test frequency: 3 times per second

Minimum substrate thickness: 0.3mm

Minimum measuring area: Ø5mm

Minimum curvature radius of convex workpiece: 3mm

Data storage: 500 groups

Interface: USB

Operation temperature: -10°C~50°C

Power supply: 3x1.5V pin AAA

Dimension: 150×70×30mm

Weight: 160g

*L is the measured value in µm.


Standard Delivery:

Main unit: 1pc

Magnetic induction preobe (FM): 1pc

Zero calibration block for FM probe: 1pc

Calibration foils (12/50/100/250/500/1000μm): 6pcs

AAA battery: 3pc

Software and USB cable: 1pc

- Magnetic induction probe (FM) measures the thickness of non-magnetic coating and non-metallic coating on magnetic metal substrate.

Substrate: steel, iron, alloy, hard magnetic steel, etc.

Coating: zinc, aluminum, chrome, copper, rubber, paint, etc.

- Eddy current probe (NM) measures the thickness of non-conductive coating on non-magnetic metal substrate.

Substrate: copper, aluminumn, zinc, tin, etc.

Coating: rubber, paint, plastic, anodized film, etc.

- Real-time temperature compensation guarantees high accuracy, thin plating and

oxide layer less than 20μm can be measured accurately

- Reduces the effects of electromagnetic interference and hand-held operation Probe can be re-matched after abrasion

- Tolerance measurement with adjustable alarm threshold

USB interface for data transmission

Coupling status indication

- Support cable printer

Datasheet

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.