Function Range
ACA 40.00A
400.0 / 1000A
ACV 40.000 / 40.00 / 400.0 / 750V
DCV 4.000 / 40.00 / 400.0 / 1000V
Resistance 400.0Ω / 4.000kΩ / 40.00kΩ
400.0kΩ / 4.000MΩ / 40.00MΩ
Continuity Threshold level (beep sound):
less than 25Ω
GENERAL
Overload Protection AC V : 750Vrms
DC V : 1000V
Diode & ohm : 600Vrms
Conductor size 35mm Max.
Low battery indication Sign appears on the display
Response time Approx. 2 times per second
Operating temperature
& humidity 0ºC ~ 40ºC
80% R.H. Max.
Storage temperature
& humidity -10ºC to 50ºC
80% R.H. Max.
Battery life Approx.100 hours on continuous use
Dimensions 183(L) × 62(W) × 20(D)mm
Weight
(battery Included) Approx. 123g
Power source CR 2032 (DC 3V) × 1
ALS-2 AC LINE SEPARATOR
Input plug Europe
Output socket 3 prong U.S. standard
Cord length 10cm
Max. Voltage/Ampere
rating 250Vac(±10%)/10Aac
Operating Temperature
& Relative Humidity 0℃~50℃ Max.80%R.H.
Weight Approx. 135g
Dimensions 145(L)x55(W)x35(D)mm