For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

YuYang YY401 Flooring Radiant Heat Flux Fire Testing Equipment (For Textile Carpets ASTM E648)

ModelYY401
ຕົ້ນກຳເນີດChina
ການຮັບປະກັນ1 ປີ
ຕິດຕໍ່
ການຊຳລະເງິນທີ່ປອດໄພ
ການຮັບປະກັນຄຸນນະພາບ
ປ່ຽນ ແລະ ສົ່ງຄືນງ່າຍ
ມີບໍລິການຈັດສົ່ງ

1. Power supply:AC 220V,50HZ;

2. Total power:2KW;

3. Timer: timing accuracy < 1s/h;

4. Heat flux measurement range: (0-15) Kw / m2;

5. Heat flux meter accuracy: ± 0.2Kw / m2;

6. Heat flux meter accuracy: <± 3%;

7. Thermal radiation temperature measurement range: 400-600 ℃, accuracy ± 0.5 ℃;

8. Blackbody temperature error: ± 5 ℃;

9. Exhaust speed: (2.5 ± 0.2) m / s;

10. Exhaust capacity: (39-85) m3 / min;

11. Porous refractory radiant panel size: 300mm × 450mm, about 900 ℃ high temperature capability;

12. Thermocouple: K diameter stainless steel sheathed thermocouple of 3.2mm;

13. Heat flux distribution requirements: at 200mm : (9.1 ± 0.4) KW / m2;

at 400mm : (5.0 ± 0.4) KW / m2;

at 600mm : (2.4 ± 0.2) KW / m2;

14. Combustion gases: propane (Customer);

15. Combustion gas flow rate: (0.026 ± 0.002) L / S;

16. Combustion burner: outer diameter ¢ 10mm inner diameter ¢ 6mm, burner tube hit 35 ¢ 0.7mm hole;

17. Flame height: 60 ~ 120mm adjustable;

18. Ignition system: high-voltage electronic ignition;

19. Powerful exhaust system: This machine is equipped with a powerful exhaust fan, when the test is completed, the system will start the exhaust fan exhaust outside.