Accuracy class: ISO 376 : 1

Nominal Load : 2MN

Relative Errors (At Reading): 

a) repeatability 0°-120°-240° (b): ≤ ±0.145%

b) interpolation (fc): ≤ ±0.090%

c) reversibility (u): ≤ ±0.240%

d) zero (fo): ≤ ±0.030% F.S.

Linearity: ≤ ±0.05% F.S.

Hysteresis: ≤ ±0.05% F.S.

Temperature Effect (10°C): 

a) on zero: ≤ ±0.028% F.S.

b) on sensitivity: ≤ ±0.024% F.S.

Effect Of Transverse Load:: 

a) at 10% of nominal load: ≤ ±0.030% F.S.

Nominal Sensitivity: 2mV/V

Sensivity Tolerance:  ≤ ±0.1% F.S.

Nominal Load:

Input Resistance: 350 ± 2Ω

Output Resistance: 350 ± 2Ω

Insulation Resistance: > 5 GΩ

Zero Balance: ≤ ± 1% F.S.

Recomended Supply Voltage: 10 V

Nominal Supply Voltage Range: 1-15 V

Maximum Supply Voltage: 18 V

Mechanical Limit Values Referred To Nominal Load:: 

a) service load: 120%

b) max permissible load: 150%

c) breaking load: >300%

d) max transverse load: 100%

e) max permissible dynamic load: 50%

Reference Temperature: +23°C

Temperature Nominal Range: -10 / +40 °C

Service Temperature: -10 / +70 °C

Storage Temperature: -20 / +80 °C

Weight (Kg) : 300kN….3MN: from 7kg to 15 kg

Protection Class (En 60529): IP65

Execution Material: Acciaio Inox / Stainless Steel

Connector Type: MIL-C-5015 7 poles male