For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

CHROMA 66203 Digital Power Meter

联系我们
安全结算
品质保证
轻松更换与退货
支持配送

- Number of channels: 3

Measured parameters: V, Vpk, I, Ipk, Is, W, VA, VAR, PF, CFi, F, THD V, THD I, E.

Voltage

- Measurement range: 15V / 30V / 60V / 150V / 300V / 600Vrms (CF=2), 6 ranges, HV option up to 1800Vrms

- Accuracy:

+ DC, 10Hz to 1kHz: 0.1% RD + 0.08% RNG

+ 1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.08% RNG

- Harmonic accuracy:

+ DC, 10Hz to 1kHz: 0.1% RD + 0.08% RNG

+ 1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.08% RNG

- Input impedance: 4MΩ

AC/DC Current

- Measurement range: 5mA / 20mA / 50mA / 200mA / 500mA / 2A / 5A / 20Arms (CF=4)

- Accuracy:

+ DC, 10Hz to 1kHz: 0.1% RD + 0.1% RNG

+ 1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.1% RNG

- Harmonic accuracy:

+ 10Hz to 1kHz: 0.1% RD + 0.1% RNG

+ 1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.1% RNG

- DC current accuracy: 0.1% RD + 0.1% RNG

Power

- Measurement range: 75mW ~ 12kW (48 ranges)

- Accuracy:

+ 47Hz to 63Hz: 0.1% RD + 0.1% RNG

+ 1kHz to 10kHz: (0.1 + 0.1 × kHz)% RD + 0.18% RNG

- Power factor accuracy: 0.001 + (15ppm / PF) × Hz

Frequency

- Measurement range: DC, 10Hz ~ 10kHz

- Accuracy: 0.06% RD

- Reference source: Voltage source

Other

- Display resolution: 5 digits

- Display update rate: 0.25 sec / 0.5 sec / 1 sec / 2 sec

- Power supply: 100~240V ±10%, 50/60Hz

- Communication: GPIB + USB or CAN + USB

- Operating temperature: 0˚C ~ 40˚C

- Storage temperature: -40˚C ~ 85˚C

- Safety & EMC: CE (including EMC & LVD)

- Dimensions (H × W × D): 133 × 212 × 420 mm

- Weight: approx. 7.5 kg

Datasheet


获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款隐私政策

快速支持

直接联系认证专家