直接联系认证专家
Glow Wire: Φ4mm±0.04mm, Ni/Cr
Temperature Range of Glow-Wire: 100~1050 (digital display)
Temperature Fluctuation: <3℃
Thermocouple: Φ0.5 or 1.0mm (conrmed before purchasing, insulation type high temperature resistance armored thermocouple)
Current Adjustment Range: 0~150A
Force Applied on Sample by Glow-Wire: 1.0N ±0.2N
Depth of Glow Wire Penetrates in the Sample: 7mm±0.5mm (controlled by mini electromagnet, ironing depth can be fine tuned)
Size of Sample Fixture: 80*80mm
Driving Mode of Specimen Trolley: DC motor drives ball screw, specimen trolley operating smoothly at a constant speed
Specimen Moving Speed: 10mm/s~25mm/s
Glowing Time: 0~99.99s (digital display, can be preset)
Time of Starting Burning: 0~99.99s (digital display, can be preset)
Flame Extinction Time: 0~99.99s(digital display, can be preset)
Ignition Ground Plate: 10mm-thickness pine wood coated with standard silk paper (12g/
Distance Between Action Point of Glow Wire and Pine Plate: 200mm±5mm
Internal Volume of Chamber : 0.5m3 (0.75m3 or 1m3 optional)
Dark Color Illuminance of Background Material in the Test Chamber : <20 Lx
Room Materials : Spray Iron Sheet
Ventilation: Φ100mm