直接联系认证专家

Tension Range*: 0 – 100 cN
Measuring Head Width**: 70 mm
Roller Width: 7, 10 mm
Calibration: According to SCHMIDT factory procedure
Accuracy: ±2 % full scale and ±1 digit; Other calibration material: ±3 % full scale or better
Overload protection: 100 % of tension range
Measuring principle: Strain gauge bridge
Measuring roller deflection: Max. 0.5 mm
Signal processing: Analog
Temperature drift: Better ±0.05 % Full Scale/ºC
Output signal:
+ Standard: 0 – 1 V DC (analog)
+ Option: Option: 0 – 10 V DC (analog) or mV/V (DMS)
Output: Shielded cable (3 m) with open ends
Damping (fg): Standard (analog): 30 Hz (other values on request)
Temperature range: 10 – 45 ºC
Air humidity: 85 % RH, max.
Power supply: +15…24 V DC, max. 21 mA regulated; Code A10: max. +5 V DC, max. 20 mA regulated
Housing material: Aluminium
Dimensions: 78 x 63 x 18 mm (LxWxH)
Weight, net (gross): With cable approx. 200 g (300 g)
Other measuring units available, such as g.
* SCHMIDT calibration material depending on tension range and roller width
** Outside dimensions of front plate
Delivery Includes: Tension sensor with transport packaging, connecting cable, operating instruction in german or english (as requested), Certificate of Compliance with the order 2.1 according EN 10204 free of charge