Pulsar measurement Quantum 2 泵控制器
制造商: Pulsar measurement Model: Quantum 2 - 联系
Controller Body Dimensions: 200 mm x 112 mm (7.87 in x 4.41 in) front, 165 mm x 105 mm (6.49 in x 4.13 in) cut-out
Weight Nominal: 1.3 kg (2.9 lbs)
Case Material: Stainless steel and polycarbonate, flame resistant to UL94 V0
Power Supply: 115 V AC +5% / -10% 50/60 Hz, 220 V AC +5% / -10%, 18-36 V AC
Volt-free Contacts: 10 total. Relays 1-5 form C (SPDT) 5 A, 220 V AC. Relays 6-10 form C (SPDT) 3 A, 220 V AC
Digital Inputs: 7 NO or NC with 24 V DC internal supply, available max. 20 mA
Analog Output (adjustable): 2 x Isolated output of 4-20mA or 0-20mA into 500 Ω (user-programmable and adjustable) 0.1% resolution
Analogue Input: Isolated input for the loop-powered device. 4-20mA source. NB: Active input on request
Serial Output: RS232 via RJ11 port
Display: 6 digits plus 12 character text, plus bar graph with direction indicators, remote communicator identifier, and program / run / test mode indicators