Technical Data

Temperature - NTC

Measuring range

-4° to 122 °F / -20 to +50 °C

Accuracy

±0.4 °F (14° to 122 °F) / ±0.2 °C (-10 to +50 °C)

Resolution

0.1 °F (-4° to 122 °F) / 0.1 °C (-20 to +50 °C)

Ambient temperature probe

Temperature - Type K TC

Measuring range

-328.0° to 2498.0 °F / -200 to +1370 °C

Accuracy

±0.7 °F (-148.0° to 392.0 °F) / ±0.4 °C (-100 to +200 °C)

±1.8 °F (-328.0° to -148.2 °F) / ±1 °C (-200 to -100.1 °C)

±1.8 °F (392.2° to 2498.0 °F) / ±1 °C (200.1 to +1370 °C)

Resolution

±0.1 °F (-328.0° to 2498.0 °F) / 0.1 °C (-200 to +1370 °C)

Temperature - TC Type S (Pt10Rh-Pt)

Measuring range

32.0° to 3200.0 °F / 0 to +1760 °C

Accuracy

±1.8 °F (32.0° to 3200.0 °F) / ±1 °C (0 to +1760 °C)

Resolution

±0.1 °F (32.0° to 3200.0 °F) / 0.1 °C (0 to +1760 °C)

Differential Pressure

Measuring range

-16 to +16 InH₂O / -40 to +40 hPa

-80 to +80 InH₂O / -200 to +200 hPa

Accuracy

±1.5 % of mv (-16 to -1 InH₂O) / ±1.5 % of mv (-40 to -3 hPa)

±1.5 % of mv (+1 to +16 InH₂O) / ±1.5 % of mv (+3 to +40 hPa)

±0.01 InH₂O (-1.20 to +1.20 InH₂O) / ±0.03 hPa (-2.99 to +2.99 hPa)

±1.5 % of mv (-80 to -20 InH₂O) / ±1.5 % of mv (-200 to -50 hPa)

±1.5 % of mv (+20 to +80 InH₂O) / ±1.5 % of mv (+50 to +200 hPa)

±0.2 InH₂O (-20.0 to +20.0 InH₂O) / ±0.5 hPa (-49.9 to +49.9 hPa)

Resolution

0.01 InH₂O (-16 to +16 InH₂O) / 0.01 hPa (-40 to +40 hPa)

0.1 InH₂O (-80 to +80 InH₂O) / 0.1 hPa (-200 to +200 hPa)

Absolute Pressure

Measuring range

240 to +460 InH₂O / 600 to +1150 hPa

Accuracy

±4 InH₂O / ±10 hPa

Resolution

1 InH₂O / 1 hPa

opt. when equipped with IR sensor

Flue gas O₂

Measuring range

0 to +25 Vol.%

Accuracy

±0.8% of fsv (0 to +25 Vol.%)

Resolution

0.01 Vol.% (0 to +25 Vol.%)

Reaction time t₉₀

20 sec (t95)

Flue gas CO

Measuring range

0 to +10000 ppm

Accuracy

±5 % of mv (+200 to +2000 ppm)

±10 % of mv (+2001 to +10000 ppm)

±10 ppm (0 to +199 ppm)

Resolution

1 ppm (0 to +10000 ppm)

Reaction time t₉₀

40 sec

H₂ only as an indicator

Flue gas COlow

Measuring range

0 to 500 ppm

Accuracy

±5 % of mv (+40 to +500 ppm)

±2 ppm (0 to +39.9 ppm)

Resolution

0.1 ppm (0 to +500 ppm)

Reaction time t₉₀

40 sec

H₂ only as an indicator

Flue Gas NO

Measuring range

0 to +4000 ppm

Accuracy

±5 % of mv (+100 to +1999 ppm)

±10 % of mv (+2000 to +4000 ppm)

±5 ppm (0 to +99 ppm)

Resolution

1 ppm (0 to +4000 ppm)

Reaction time t₉₀

30 sec

Flue gas NOlow

Measuring range

0 to +300 ppm

Accuracy

±5 % of mv (+40 to +300 ppm)

±2 ppm (0 to +39.9 ppm)

Resolution

±0.1 ppm (0 to +300 ppm)

Reaction time t₉₀

30 sec

Flue Gas NO₂

Measuring range

0 to +500 ppm

Accuracy

±5 % of mv (+100 to +500 ppm)

±5 ppm (0 to +9.99 ppm)

Resolution

0.1 ppm (0 to +500 ppm)

Reaction time t₉₀

40 sec

Flue Gas SO₂

Measuring range

0 to +5000 ppm

Accuracy

±5 % of mv (+100 to +2000 ppm)

±10 % of mv (+2001 to +5000 ppm)

±5 ppm (0 to +99 ppm)

Resolution

1 ppm (0 to +5000 ppm)

Reaction time t₉₀

30 sec

Efficiency (calculated)

Measuring range

0 to +120 %

Resolution

0.1 % (0 to +120 %)

Flue Gas loss (calculated)

Measuring range

0 to +99.9 %

Resolution

0.1 % (0 to +99.9 %)

Flue Gas dewpoint (calculated)

Measuring range

0 to +99.9 °Ctd

Resolution

0.1 °Ctd (0 to +99.9 °Ctd)

Flue Gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max

Accuracy

calculated from O₂ ±0.2 Vol.%

Resolution

0.01 Vol.%

Flue gas H₂S

Measuring range

0 to +300 ppm

Accuracy

±5 % of mv (+40 to +300 ppm)

±2 ppm (0 to +39.9 ppm)

Resolution

0.1 ppm (0 to +300 ppm)

Reaction time t₉₀

35 sec

Flue Gas CO₂ - NDIR

Measuring range

0 to +50 Vol.%

Accuracy

±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%)

±0.5 Vol.% + 1.5 % of mv (25 to 50 Vol.%)

Resolution

0.01 Vol.% (0 to 25 Vol.%)

0.1 Vol.% (> 25 Vol.%)

Reaction time t₉₀

10 sec

Velocity / Volume flow

Measuring range

0 to +7874 fpm / 0 to +40 m/s

Resolution

19.7 fpm (0 to +7874 fpm) / 0.1 m/s (0 to +40 m/s)

Methane (CH₄)

Measuring range

100 to 40000 ppm

Accuracy

< 400 ppm (100 to 4000 ppm)

< 10 % of mv (> 4000 ppm)

Resolution

10 ppm

Min. O₂ requirement in flue gas

2 % + (2 x mv methane)

Reaction time t₉₀

< 40 sec

Response factor

1

Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.

Propane (C₃H₈)

Measuring range

100 to 21000 ppm

Accuracy

< 400 ppm (100 to 4000 ppm)

< 10 % of mv (> 4000 ppm)

Resolution

10 ppm

Min. O₂ requirement in flue gas

2 % + (5 x mv propane)

Reaction time t₉₀

< 40 sec

Response factor

1.5

Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.

Butane (C₄H₁₀)

Measuring range

100 to 18000 ppm

Accuracy

< 400 ppm (100 to 4000 ppm)

< 10 % of mv (> 4000 ppm)

Resolution

10 ppm

Min. O₂ requirement in flue gas

2 % + (6.5 x mv butane)

Reaction time t₉₀

< 40 sec

Response factor

2

Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.

General technical data

Dimensions

13 x 5 x 17 in. / 330 x 128 x 438 mm

Operating temperature

23.0° to 113.0 °F / -5 to +45 °C

Housing

ABS

Protection class

IP40

Battery type

lithium batteries

Battery life

5 h

Power supply

AC mains unit 100V to 240V (50 to 60 Hz)

DC electric tension input

11V to 40V

Trigger input

Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA

Max. humidity load

70 °C dewpoint temperature

Dewpoint calculation

0 °Ctd; 99 °Ctd

Max. dust load

20 g/m³ dust in flue gas

Max. neg. press./flue gas

-4.4 psi / -300 mbar

Max. pos. press./flue gas

0.7 psi / 50 mbar

Hose length

16.2 m (corresponds to 5 probe hose extensions)

Pump flow

1 l/min. with through-flow monitoring

Maximum

250,000 readings

Storage temperature

-4.0° to 122.0 °F / -20 to +50 °C

Weight

169 oz. / 4800 g

Details

Datasheet

Manual

The testo 350 Portable Emission Analyzer

Whether you are testing for compliance or troubleshooting and tuning the testo 350 portable emission analyzer offers everything you need!

Control Unit - Provides remote control operation up to 300 ft away

  • Color graphic display is easy to see in dark or bright conditions
  • Go wireless with long-range 300 ft. Bluetooth (or wired to over 3,000 ft.) to eliminate long sample lines

Analyzer box - for high accuracy measurements

  • Contains up to six sensors, pumps, gas path, sample conditioning, and more
  • Conditions the gas sample automatically, thermoelectric (peltier) chiller as required by regulatory agencies

Test up to six gases simultaneously, or swap sensors out for additional parameters with field replaceable pre-calibrated digital sensors

  • Dilution system for the widest testing ranges and greatest sensor protection
  • Sample conditioning utilizes a thermoelectric chiller and a peristaltic hose pump for controlled water removal and EPA compliance
  • Automatic flow-controlled high strength pump
  • Proven sample gas path with Teflon® lined hoses
  • Continuous temperature compensation for assured accuracy
  • Flow rate and sensor temperature monitoring for US EPA CTM-030, -034, ASTM D6522, and SCAQMD 1110.2 and 1146 requirements
  • User defined programs with onboard memory to 250,000 values
  • User configured testing programs
  • Emission Rates: Real time display w/ EPA Method 19 Calculations
  • Mass flow and emission rates with pitot tube
  • User defined O2 reference for EPA and state reporting

350-Measurement-Capabilities

testo-350-brochure-2015b

 

A wide selection of probes for every application

Built for simple field service

The testo 350 represents the latest in portable emission analyzer technology for longer up-time in the field and lower cost of ownership.

testo 350 portable emission analzyer back access

  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化

注册收新闻 - 获得优惠活动的机会