For full functionality of this site it is necessary to enable JavaScript.

TRANSCOM T5230A 矢量网络分析仪

 T5230A is a high performance VNA, large frequency range, large dynamic range, low Noise level, low trace noise, it can be widely used for microwave device measurement in wireless communication, broadcast, TV device, radar device and semiconductor.

  • Large frequency range: 300kHz to 3.0GHz
  • Large dynamic range: >125dB (IFBW=10Hz), 130dB typ.
  • Low noise level: <-120dbm ifbw="10Hz)</li">
  • Low trace noise: 1mdB rms (IFBW=3kHz)
  • High measurement speed: 125μs/point (IFBW=30kHz)
  • High effective directivity: >45dB
  • Remote Control: LAN/GPIB/USB
  • Very low power consumption
  • “One-key-test” solution
Details

 Datasheet

Measurement Range

 

Impedance

50Ω or 75Ω

Test port connector

N-type, female

Number of test ports

2

Frequency range

300kHz to 3GHz

Full CW frequency accuracy

±5×10-6

Frequency resolution

1Hz

Number of measurement points

2 to 10001

Measurement bandwidths

1Hz to 30kHz

(with 1/1.5/2/3/5/7 steps)

Dynamic range

(IF bandwidth 10 Hz)

125dB, typ.130dB

Measurement Speed

Measurement time per point

125μs

Source to receiver port switchover time

10ms

Typical cycle time versus number of measurement points

Number of points

(IFBW 30kHz)

51

201

401

1601

Uncorrected

(Start 300 kHz, stop 10 MHz)

13ms

52ms

104ms

413ms

Full two-port calibration

(Start 300 kHz, stop 10 MHz)

46ms

123ms

226ms

844ms

Uncorrected

(Start 10 MHz, stop 3 GHz)

7ms

27ms

53ms

207ms

Full two-port calibration

(Start 10 MHz, stop 3 GHz)

34ms

73ms

125ms

434ms

Manufacturer

 Transcom

Option:

1- 5301N50 High Precision, DC to 3GHz, 50Ω, N-type Calibration Kit Set

5301N50-30101 High Precision, SOL(N-f), 50Ω, DC to 3GHz

5301N50-30102 High Precision, SOL(N-m), 50Ω, DC to 3GHz

5301N50-30103 High Precision, THROUGH N(f) - N(f), 50Ω, DC to 3GHz

5301N50-30104 High Precision, THROUGH N(m) - N(m), 50Ω, DC to 3GHz

2- 5901N50 High Precision, DC to 9GHz, 50Ω, N-type Calibration Kit Set

5901N50-90001 High Precision, SHORT N(f), 50Ω, DC - 9GHz

5901N50-90003 High Precision, OPEN N(f), 50Ω, DC - 9GHz

5901N50-90005 High Precision, LOAD N(f), 50Ω, DC - 9GHz

3- 5901N50-90007 High Precision, THROUGH N(f) - N(f), 50Ω, DC - 9GHz

5901N50-90002 High Precision, SHORT N(m), 50Ω, DC - 9GHz

5901N50-90004 High Precision, OPEN N(m), 50Ω, DC - 9GHz

5901N50-90006 High Precision, LOAD N(m), 50Ω, DC - 9GHz

5901N50-90008 High Precision, THROUGH N(m) - N(m), 50Ω, DC - 9GHz

4- 5902S50 High Precision, DC to 9GHz, 50Ω, SMA Calibration Kit 5,050

5902S50-90201 High Precision, SOL(SMA-f), 50Ω, DC to 9GHz

5902S50-90202 High Precision, SOL(SMA-m), 50Ω, DC to 9GHz

5902S50-90203 High Precision, THROUGH SMA(f) - SMA(f), 50Ω, DC to 9GHz

5902S50-90204 High Precision, THROUGH SMA(m) - SMA(m), 50Ω, DC to 9GHz

5- T5_RFCAB-NmNm_18101 Test Cable - DC to 18GHz, 50Ω, N(m)-N(m) , 1m

6- T5_RFCAB-NmSMAm_18102 Test Cable - DC to 18GHz, 50Ω, N(m)-SMA(m), 1m

7- T5_RFCAB-NmNm_60101 Test Cable - DC to 6GHz, 50Ω, N(m)-N(m), VSWR<1.1, IL<1.2db span="">

8- T5_RFCAB-NmSMAm_60102 Test Cable - DC to 6GHz, 50Ω, N(m)-SMA(m), VSWR<1.1, IL<1.2db span="">

9- VNA_ATE Automated test software for VNA

10- T5_RM VNA rack mount kit

11- T5_FH VNA front handle kit

 

  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化

注册收新闻 - 获得优惠活动的机会