For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Máy đo nồng độ canxi trong đất Eijkelkamp 08.53 (0 -> 200 g/kg, 1 g/kg)

Model08.53
Liên hệ
Thanh toán an toàn
Hỗ trợ chuyên nghiệp
Đổi trả dễ dàng
Giao hàng tận nơi

Ứng dụng

Nghiên cứu vật lý đất trong phòng thí nghiệm


Thông số kỹ thuật

Số lượng mẫu tối đa: 5

Đặc điểm kỹ thuật mẫu: Bị xáo trộn

Phạm vi đo: 0 -> 200 g/kg

Thông số đo được: Hàm lượng cacbonat

Độ chính xác khi đọc: 1 g/kg

Trọng lượng: 30 kg

Kích thước gói: 146 x 62 x 59 cm

Description

A good amount of calcium carbonate in the soil shows that the pH is good, and acidity is not too high. This is important information when researching the quality of soil. It shows that the conditions for soil life are good. The determination of carbonate content is an important step in the soil classification process, and research how suitable soil is for its intended use. 


The calcimeter design 

This calcimeter is suitable for use in a professional lab and made to be sturdy and durable. Where possible, vulnerable glass was replaced with synthetic materials. The design is stable and ergonomic, to ensure safe use of hydrochloric acid. 

The calcimeter comes with reaction vessels and test tubes (without reagents). A reaction takes approximately one hour. Carbonates that are hard to dissolve, such as sea shells, take more reaction time.


Using the calcimeter

The quantity of sample needed is determined beforehand by treating a part of the sample with hydrochloric acid on a watch glass. The carbonate content is estimated on the basis of the extent and period of bubbling. Based on this estimate, the quantity of sample for the analysis is determined.


Accurate results

This calcimeter does not use a balloon to keep the CO2 separate from the water (to prevent any gas from dissolving in the water). This results in much more accurate measuring results. To ensure accuracy with repeated measurements, a series should be executed in a room where changes in temperature do not exceed 4°C. The reagents used must also meet the standards for analysis.

Note that other gasses may be released as well, for instance if the soil is polluted. The gas will then have to be purified first and the CO2 will have to be determined otherwise.


Applications

Soil physical laboratory research