Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Power [kW]: ±600
Output Voltage [V]: 20-2000
Output Current [A]: ±800
Size (WHD) [mm]: 3410x1955x1200
Weight [kg]: 3500
Basic parameters
Output mode: CV, CC,CP, CR, programmable and battery simulation functions
Energy feedback: Receive load energy and feed it back to the grid
Isolation function: Electrical isolation of input and output
Parallel function: Multiple sets of the same model can be installed in parallel
DC output
Voltage
Resolution (V): 0.01
Accuracy: ±0.1% F.S.
Ripple(RMS): 0.1% F.S (resistive load)
Voltage slew rate: 200V/ms
Current
Resolution (A): 0.01
Accuracy: ±0.1% F.S.
Ripple(RMS): 0.1% F.S. (resistive load)
Slope: 500A/ms
Rise time: ≤2ms (10%~90% rated current)
Switching time: ≤4ms (switching from -90% to +90%)
Peak time: 60s (1200V type)
Battery simulation
Battery type: Different battery types such as lithium manganate, lithiumcobaltate, lithiumiron phosphate, nickel-hydrogen, ternary lithium, lithiumtitanate, andlead-acid batteries can be simulated
User-defined battery types and open first, second and third-order RCbatterymodels are supported
Parameter: Number of batteries in series connection, number of batteries in parallel connection, initial SOC, initial temperature, internal resistance, cell capacityand other parameters
Interface: Import of CSV user-defined model is supported
Real-time performance: 1ms command refresh rate
Virtual resistance
Scope: -2 to +2 Ω
Resolution: 1 m Ω
Universal programmable
Programming steps: 200 steps
Programming parameters: Voltage/current, rise time, hold time, trigger pulse output
Rise time range: 1ms-99999s
Flat top time range: 1ms-99999s
Minimum programming time step: 1ms
Editing mode: Add, delete, import, export
Operation mode: Run, stop, loop
Trigger mode: Automatic, manual, external
Measurement
Voltage accuracy: ±0.1% F.S.
Voltage resolution (V): 0.001
Current accuracy: ±0.1% F.S.
Current resolution (A): 0.001
Power accuracy: ±0.2% F.S.
Power resolution (KW): 0.001
AC input
Wiring mode: Three-phase four-wire ABC+PE
Frequency (HZ): 47 - 63
Voltage range (V): 380V±15%
Power factor: 0.99 @ full load
Efficiency: Models of 300kW and above: > 94%, others: > 90%. Harmonic current: ≤3%
Others
Protection function: OVP, OCP, OPP, OTP, Phase loss protection Communication interface Standard configuration: LAN; optional: RS485, CAN
External interlocking: External interlocking input is normally on/off; external interlocking output isnormally on/off.
Trigger signal: Trigger input/output
Control and display: Touch screen control and remote host computer control; display voltage, current, power and operation trend chart
Bleeder resistor cabinet (optional): Under abnormal working conditions of the system, energy will be releasedthrough the bleeder resistor cabinet to ensure the safety of the test object
Capacitance compensation component (optional): Voltage drop caused by cable impedance and the voltage ripple fromtheunit under test
Insulation and withstanding voltage: 10MΩ/DC500V;3600VAC(5000VDC)/1min
Cooling mode: Fan cooling
Operating temperature: -10℃~40℃
Relative humidity: 10% to 90% RAH
Altitude: ≤2000m