- Input Voltage Range: Universal input 47 ~ 440 Hz: 85~264 VAC
120~380 VDC
- Power Rating:
XTA:200W, XTB:400W
- Input Current:
XTA: 85VAC in 200W out, 4.5 A
XTB: 85VAC in 283W out, 5.0 A
- Inrush Current: 230 VAC @ 25°C: 50A
- Undervoltage Lockout: Shutdown, 65 ~ 74 VAC
- Fusing:
XTA: 250V, F5A HRC
XTB: 250V, F6.3A HRC
Output
- Line Regulation: For ±10% change from nominal line, ±0.1%
- Load Regulation: For 25% ~ 75% load change, ±0.2 %
- Ripple and Noise: 20MHz 100mV or 1.0% pk-pk
General:
- Isolation Voltage:
Input to output: 3000VAC
Input to chassis: 1500VAC
- Efficiency: 230VAC, 400W @ 24V, 90% Nom
- Leakage Current: 250VAC, 60Hz, 25°C, 1.5mA Max
- Bias Supply: Always on, current 250mA. 500mA option available, 4.8~5.2VDC
Environmental
- Operating Temperature: -20 ~ +70 °C
- Storage Temperature: -40 ~ +85 °C
- Relative Humidity: Non-condensing, 5 ~ 95 %RH