Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Manufacturer: BIOBASE
Model: BIOBASE2000
Origin: China
Warranty: 12 months
Features:
- 4 microplates,2 pipetting probes
- 192 sample positions , 96 dilution positions,23 reagent positions, 16 common reagent positions,48 QC positions.
- All sample & reagent positions can be editable.
Sample pipetting unit
Sample rack: 24 sample tubes/rack, at most 23 racks
Primary sample tubes: 11.5-13mm
Pipetting: 8ul~1000ul, (10ul) CV<5%
Time to dispense: 12 minutes adding 96 samples
Dispensing system: 1 aspirating-dispensing probe with X-Y-Z movement;dilution system with a syringe of 1000ul, continuous flow washing station.
Reagent pipetting unit
Reagent racks: 2 reagent tanks(60ml)/ rack, at most 23 racks
QC racks: 24 positions/QC rack, at most 23 racks
Pipetting : 8ul~1000ul,1ul stepping
pipetting precision: (100ul )CV≤0.5%
Time to dispense: 3 minutes(typical)^100ul of 96 reagents to plate from reagent bottle
Programmable: Yes(options & parameters)
Wash containers: 3 wash buffers at 2.0L,1 wash buffers at 5.0L,with level-sensing
Waste containers: 25L with waste full sensor
Washing system: two 8 nozzle manifolds, one to dispense and the other one to aspirate
Washing residual: <2μl
Reading system: 8 independent photometric channels with mono and bichromatic reading capability
Photometric range: 0.000 ~3.000 OD
Spectral range: 400-700nm
Optical filters: 2 precision filters (450and 630nm); 2 more on request (4 filters max, 405 nm, 450 nm, 492 nm and 630 nm)
Reading inaccuracy: inaccuracy±1% from 0.000 to 1.500 OD, ±2% from 1.500 to 3.000 OD
Incubators: 4 independent units
Programmable: Yes
Temperature range: RT to 45 °C
Temperature accuracy: ±0.5℃
Temperature staility: ±0.5℃
Software system: Windows 7/8/107 or above, LIS system available
Function application: work list set up, patient reports and result filing; calibration curve storage for each carried out test
Data reduction: cut-off (qualitative)
Power Supply: AC 110/220V±10%,50/60Hz,450W
External Size(W*D*H): 1235*710*880mm
PackageSize(W*D*H): 1370*850*1439mm
Gross Weight: 220kg
Brochure