Measuring Mode: Inner four-wire + outer four-wire
Maximum number of test points: 1024
AC Output Voltage: 50-1000V DC
DC Output Voltage: 0-1500V DC
High Voltage Output Accuracy: ±3%
High Voltage Measurement Accuracy: ±3%
High Voltage Measurement Time: 0.02s - 60s, user delay not included
Low Voltage Measurement Time: 0.02s - 60s, user delay not included
O/S Measurement Time: 500μS (1024 points, user delay not included)
Test Items and Range
O/S,IntermienceO/S,QuickIntermience OpenCircuit: 2kΩ-100 kΩ
Inner Four-wire Test Conductance: 0.1Ω-1MΩ
Outer Four-wire Conductance Test: Measurement Range: 1μΩ-100Ω; Current Signal: ≤1A
AC Hipot Leakage Current: 0.01mA-10mA
DC Hipot Leakage Current: 0.1μA-5mA
DC Hipot Insulaon Resistance: 1MΩ-5GΩ
DC Resistance:
+ MeasurementRange: 100mΩ-20MΩ
+ Level Signal: 0-5V
+ Current Signal: ≤10mA
LCR:
+ CapacitancesMeasurementRange: 10pF-100mF
+ ResistanceMeasurementRange: 100mΩ-20MΩ
+ Inductance Measurement Range: 10nH~100H
+ Frequency Signal: 50Hz/60Hz/100Hz/120Hz/1kHz/10kHz/50kHz
+ RangeMode: AUTO/HOLD
+ Level Signal: 0.1/0.3V/1V
Diode/Zener diodes:
+ Test Range: 0-100V
+ Test Signal: 1mA/100V
Single-Side Test: Yes
O/S Terminal Judge: Yes
Advanced Funcons: Programmable connuous test/ Automac point search/ Auto-diagnosis
Test Scan Mode: Automac/manual/external
Measurement Signal: low voltage measurement signal
Storage Memory: Number of test files up to 500 sets
OS Voltage: 5V
Panel: System/ Rapid/ Edit/ Funcon
Indicator: Pass/ Fail HV LED red-green indicator lights/ Screen Display/ Sound
Dimension (W*H*D): 483*265*510 mm
Weight: 25 kg