Current ranges:
20 A
200 A
2000 A
AC rms
Output sensitivity (AC-coupled):
1 mV
10 mV
100 mV
1 mV per A
Load impedance: 100 kΩ minimum
Accuracy: at +25°C
±1% of range (45 Hz to 65 Hz)
Linearity:
10% to 100% of range
±0.2% of reading
Noise:
8 mV AC rms (30 A)
2 mV AC rms (300 A, 3000 A)
Frequency range: 10 Hz to 20 kHz (-3 dB)
Phase error:
< ±1° (45 Hz to 65 Hz)
±10° (at 20 kHz)
External field:
with cable > 200 mm from the head
±1% of range
Power supply: 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
Temperature Coefficient: ±0.08% of reading per °C
Working voltage: see Safety standards section
600 V AC rms or DC
Head Circumference: 610 mm (24 in)
Head cable diameter: 14.3 mm (0.56 in)
Head bend radius: 38.1 mm (1.5 in)
Cable length (head to electronics): 2 m (6.56 ft)
Output connection: Molded 4 mm safety plugs (not integrated)
Operating temperature range: 0°C to +70°C (32°F to 158°F) (head and electronics)
Storage temperature range:
-40°C to +105°C (-40°F to 221°F) (head)
-20°C to +85°C (-4°F to 185°F) (electronics)
Operating humidity: 15% to 85% (non-condensing)