Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

ELECTRICAL PARAMETERS
Accuracy class:
0.02%, 0.05%
Power supply: AC 220 V±10% or 110 V±10%, 50/60Hz
Power consumption: <30VA
Warming-up time: <30min
Voltage measurement
U1, U2,U3: 6.25V, 12.5V, 25V, 50V, 100V, 200V, 400V, 800V
(switch automatically), max 1000V
Range: (0-120%)RG
Resolution: 0.01%RG
Accuracy: 0.02%RD or 0.05%RD
Current measurement
I1, I2, I3: 0.25, 0.5, 1, 2.5, 5, 10, 25, 50, 100A(switch
automatically)
Range: (0-120%)RG
Resolution: 0.01%RG
Accuracy: 0.02%RD or 0.05%RD
Power measurement
Active accuracy: 0.02%RD or 0.05%RD
Reactive accuracy: 0.05%RD or 0.1%RD
Apparent accuracy: 0.02%RD or 0.05%RD
Energy measurement
Active accuracy: 0.02%RD or 0.05%RD
Reactive accuracy: 0.05%RD or 0.1%RD
Phase measurement
Range: 0.00°-359.99°
Resolution: 0.001°
Accuracy: 0.02° (voltage ≥50V and current ≥250mA)
Frequency measurement
Range: 45-65Hz
Resolution: 0. 001Hz
Accuracy: 0.002Hz
Power factor measurement
Range: -1.0 ~ 0 ~ +1.0
Resolution: 0.0001
Accuracy: 0.0005
Electric energy pulse output
Pulse constant range: 1-2880000000
Output frequency of max. pulse: 600 kHz
Load capacity: >2mA
Default pulse output frequency: 10kHz-600kHz
Energy pulse Input
Input range of pulse constant: 600-700000
Setting range of test pulse: 1-999999999
Max. pulse receiving frequency: 2MHz
Pulse input level: 5V
Voltage/current harmonics measurement
Times: 2-31
Error: 0.05%
Distortion degree error: 0.05%
Transducer measurement
DC voltage range: ±1, ±5, ±10, ±20 V
Accuracy: 0.01%
DC current range: ±1, ±2.5, ±5, ±10, ±20mA
Accuracy: 0.01%
Ripple error: 1%
DC measurements (option)
DC voltage: 50V, 100V, 200V, 400V, 800V (switch
automatically), max 1000V
Range: (0 -120%) RG
Resolution: 0.01% RG
Accuracy: 0.02% RD
DC current: 0.1A, 0.3A, 1A, 3A, 10A, 30 A(switch
automatically)
Range: (0-120%) RG
Resolution: 0.01% RG
Accuracy: 0.02% RD
MECHANICAL PARAMETERS
Dimensions (W×H×D) (mm): 440×360×160
Weight (kg): 10
ENVIRONMENTAL CONDITIONS
Operating temperature: 10°C ~ 30°C
Relative humidity: ≤85%