Size Range: 0.3 to 25 μm
Size Channels: Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm variable binning
Flow rates / Accuracy: 0.1 CFM (2.83 LPM) / ± 3% or 1.2 LPM ± 3%
Concentration Limits: 15,000,000 particles/ft3 @ 10% coincidence (per ISO 21501-4), 30,000,000 particles/ft3 @ 10% coincidence (as tested and validated1)
Aerosol Concentration Range: 0.01 to 20,000 μg/m³
Light Source: Long life laser diode
Resolution: 0.00003 μg/m3
Counting Efficiency: 50% @ 0.3 μm; 100% for particles >0.45 μm per JIS
Zero Count: <1 count / 60 minutes (<1 particles / 6 ft3). No fault count subtraction. No appreciable drift.
Count Modes: Particles/second, Real-Time Meter, cumulative/differential count/m³ and count/ft³, and mass concentration (PM)
Count Alarms: 1 to 9,999,999 counts
Calibration: NIST traceable
Display: 4.3″ (10.9 cm) WQVGA (480×272) color touch screen
Optional Printer: External thermal printer available
Vacuum Source: Internal pump with automatic flow control
Filtered Exhaust: Internal HEPA filter
Number of Channels: 6
Custom Size Channels: Calibration for custom size channels available
Audible Alarm: Adjustable built-in alarm
Communication Modes: Ethernet, USB, Wireless 802.11 b/g (Optional), RS485 or RS232
Environmental Sensors (AQM1): Includes NDIR CO2 (0-5000 ppm, resolution 1 ppm, accuracy ±1% FS, Response rate 20 seconds), temperature and relative humidity probe 32º to 122ºF (0º to 50ºC) ±1ºF (0.5ºC), 15-90% ±2% RH
Environmental Sensors (AQM2): Includes all sensors in the 5301-AQM1 and TVOC PID (standard on the 5301-AQM2), 0-50 ppm / minimum detection level 5 ppb, accuracy ±1.5%, Response rate <3 seconds
Alarm: Alarms for particle counts (any size channel), sensor failure, environmental sensors, and flow rate
Standards: ISO 21501-4 and JIS B9921
Instrument Calibration: Recommended minimum once per year. Gases, temperature and humidity sensors field calibratable.
External Surface: Stainless steel
Dimensions (L x W x H): 5.22 x 3.81 x 9.42 in (13.3 x 9.7 x 23.9 cm) includes barb fittings
Weight: 4 lb (1.8 kg)
Accessories: User manual + Instrument Management Software (IMS) on USB flash drive, isokinetic probe, temperature relative humidity sensor, purge filter, USB cable, and power supply
Optional Accessories: Printed manual, carrying case, external printer, barbed fittings, and sample tubing
Data Storage: 45,000 sample records (rotating buffer) including particle count data, environmental data, locations, annotations, and times. Scrollable on screen or printout.times. Scrollable on screen or printout
Sample Time: 1 second to 99 hours
Power: 110 to 240 VAC 50/60 Hz universal in-line power supply
Operating Conditions: 41-104ºF (5-40ºC) / 20% to 95% non-condensing
Storage Conditions: 32-122ºF (0-50ºC) / Up to 98% non-condensing