Dimensions: 186 mm (H) x 133 mm (D) (7.3 in (H) x 5.2 in (D))
Cable Entry: 2 off cable glands 4.5 mm to 10 mm (0.2 in to 0.4 in); Torque to 2 NM
Mounting:
IMP3 - 3 m (9.8 ft) version: 1.5 in BSP/NPT
IMP6 - 6 m (19.7 ft) version: 1.5 in BSP/NPT
IMP10 - 10 m (32.8 ft) version: 2 in BSP/NPT
Suits BSP & NPT, parallel and tapered
Weight Nominal: 1kg (2.2 lb)
Enclosure Protection: IP67
Temperature (Process): -40°C to +65 °C (-40 °F to +149 °F )
Temperature (Ambient): -40 °C to +80 °C (-40 °F to +176 °F)
Input Voltage Range: 11-30 V, 3.5-22mA
Accuracy: ±0.25% or 6 mm (0.2 in) whichever is greater
Resolution: ±0.1% or 2 mm (0.1 in) whichever is greater
4-20mA Outputs: Resolution 5 μA; both active and passive outputs
Temperature Compensation: Via internal temperature sensor 0.5 °C (± 32.9 °F) accuracy. Level and volume conversion are installed allowing linearisation for tank shapes.
PC Interface: All parameters can be accessed and changed through PC Suite software. Echo traces may be viewed on-screen.