Sensor Body Dimensions: 78 mm D x 195 mm H (3.1 in x 7.7 in)
Weight: Nominal 1.5 kg (3.3 lb)
Enclosure Material/Description: Valox 357. Wiper blade — Stainless steel
Transducer Cable Extensions: 4-core screened
Maximum Separation: 200 m (656.2 ft)
Mounting Connection: 1” NPT or BSP
ENVIRONMENTAL
IP Rating: IP68
Max. & Min. Temperature (Electronics): -20 °C to +50 °C (-4 °F to +122 °F)
CE Approval:
2014/30/EU & 2014/35/EU — EMC Directive. Standards applied: EN 61010-1:2010 / EN 61326-
1:2013 / EN 55011 / EN 61000 (3-2 / 3-3 / 4-2 / 4-3 / 4-4 / 4-5 / 4-6 / 4-7 / 4-11
ATEX Approval: Viper transducer must be within a safe area
PERFORMANCE
Accuracy: 0.25% of the measured range or 10 mm (0.4 in), whichever is greater
Resolution: 0.25% of the measured range or 10 mm (0.4 in), whichever is greater
Max Range: 10 m (32.8 ft)
Min Range: 300 mm (11.8 in)
Minimum Sludge Density: 0.5% concentration