Tension Range: 0 – 5000 cN
Measuring Head Width*: 120 mm
SCHMIDT Calibration Material**: PA: 0.80 mm Ø
Calibration: According to SCHMIDT factory procedure
Accuracy: ±1 % full scale and ±1 digit or better; Other calibration material: ±3 % full scale and ±1 digit or better
Overload protection: 100 % of tension range
Measuring principle: Strain gauge bridge
Measuring roller deflection: Max. 0.5 mm
Natural frequency: Approx. 500 Hz, depending on tension range
Signal processing: Digital 12-bit A/D converter, Internal averaging up to 4 sec.
Communication frequency: 200 readings/s
Temperature drift: Less than ±0.05 % full scale/°C
Output signal: RS-422 (57600, 8, N, 1)
Temperature range: 10 – 45 ºC
Air humidity: 85 % RH, max.
Power supply: +15…24 V DC, 50 mA (regulated)
Housing material: Aluminium
Dimensions: See dimensions
Weight net (gross): Approx. 420 g (580 g)
Other tension ranges and measuring head widths available on request.
Other measuring units available, such as g or kg
* Outer dimensions of front plate
** Suitable for 95 % of applications PA = Polyamide Monofilament
Delivery Includes: Tension sensor with transport packaging, operating instruction in german or english (as requested), Certificate of Compliance with the order 2.1 according EN 10204 free of charge